The W version officially works with 10.x or higher.
MiVoice Business Release 10.0
New Features and Capabilities
New phone 6920w, 6930w, and 6940w models, as well as MiNET software is added to the 6900 series of MiNET IP Phones.
But there is FW and tools available for download at Mitel...
Please use attached file. Migration starts on page 5https://files.engineering.com/getfile.aspx?folder=bf41bdad-9e37-4739-a55c-97265778ce2c&file=How_to_upgrade_3300_ICP_bootloader_with_no_Disk_Drive_R4-1.docx
Compact Flash slot 2:
In MiVoice Business Release 9.1 or later, the AX Controller requires a single 16 GB Compact Flash (CF).
The 16 GB CF must be inserted in the Compact Flash 2 slot of the controller, leaving the Compact Flash
1 slot empty
If the user uses a headset, the user can answer the phone by pressing the line key with the handset still on the IP set.
The headset must be connected to the headset port on the IP set, and a headset key must be programmed and activated.
If you use SIP trunk try the following SIP Peer Profile options:
- Public Calling Party Number Passthrough --> YES
- Use Original Calling Party Number If Available --> YES
With ISDN it is not possible.
BTW the root password is root. If you fill in the password mayby you will see what is the problem. I had this with an AX and when I logged in I saw why.
What Bill means is the new reconcile command:
RECONCILE CLUSTER AND RDN
Qualifiers:
None
Purpose:
•Removes the existing DoNotSpawnReconcileCCNetworkTable flag.
•Triggers reconcile cluster and RDN table directly.
Details:
You cannot run this command during an SDSsynchronization...
What happens when you dial the number of the RAD instead of the hunt group number where the RAD is in?
Does the huntgroup has call rerouting on it? Remove this and test again.
When I make a RAD the 'Answer Plus Expected off-hook timer' is 2 seconds longer then the 'Message lenght timer'. In...
Group Licensing allows you to move licenses from one MiVoice Businesssystem to another within the license sharing group (called an "applicationgroup") without having to make changes to the individual applicationrecords on the AMC.
When the operator closes the application it will go automatically into Night1 service. Program a rad as Night1 in Call Rerouting Always for the destination. The operator decides when de console is in Dat or Night service. We have bad experiences with automatically Day/Night service.
Have you tried to put a pause (multiple) between the feature access codes:
Programming
1. System Options form
- Program the Speed Call Pause Duration.
2. System Speed Calls form
- Add a P in the Actual Number field where you want a pause to occur.
Because you have 4 ports I think you've got a CX/CX-I. To increase the ports to a max. of 16 you need to add a DSP-II module. If you have a CX-II/CXi-II you also have a max of 16 but no need of additonal hardware.