Hello All,
I am hoping that someone will be kind enough to supply me with the firmware passwords for use with the TN2302AP Media Processor DEFINITY card.
This password is required in order to make changes to the card from a telnet session (to the Med Pro; not to the PBX). Specific changes...
Hi Chris,
Many thanks for this information; sometimes it's hard for me to find out things like that.
Unfortunately, when telnetting with plymouth as authentication, I receive the following error when -
DL:DV32->
DL:DV32-> Invalid command for this password
DL:DV32->
Any ideas ? To me...
Thanks, Definity ... Do you find that it is reliable ?
Also, how far away are the VuStation unit & IMUX ? Over 100 feet ?
Are you supplying any supplemental power to the line between the IMUX and VuStation ?
Beware of old software versions by the way ... Some are dodgy. Did you know that...
Video-Conferencing using PolySpan VuStation 512 & TN556D card as ISDN-2 / BRI source ...
... Does anyone have any experiance of this ?
If you have been successful, how are you configuring the switch and which of the following are you using ?
(1) WCBRI stations only feeding MUX
(2) Data...
I'm trying to create a data module on an R.3 switch for use with "sav ann" but keep getting "Announcement data module not available" back. The ann. data module definitely exists (as do the 4 netcons). Additionally, the circuit pack a volatile TN750B, is in the right slot...
Analogue boards are prone to blowing since they can take a hammering. It's for this reason that it is recommended to stretch intuity ports out over several boards. Also the boards are not capable of servicing 16 ports simultaneously (capacity issue) which is not great.
Have you tried popping...
Shame that there is no way to make several PBXes share the same list.
We have DEFINITY ECS systems across Europe in Si / SCC boxes but have to administer the cha abbr dia sys on each one.
Maybe a thought for future versions, Avaya. Connection via C-LAN to a server or service running on 2000...
cha sys cdr
sta cdr link
busy / rel cdr link
Connect via DB25 to EIA / DCE port on back of switch.
It's easy to hook up a PC using Hyperterminal or Procomm Plus. This will let you save the session's text to a server share somewhere. Our CDR data is now 26MB.
You can easily manipulate using...
Personally I think that by far the best way to print from DSA is to select, copy and paste to notepad.
This allows you to show several screens per page.
Better still, get a massive monitor and paste to notepad windows for on-screen referal / comparison. This is useful ;-)
But that's not...
Are you 100 % certain that the stations' CORs are the same ? Just wondering, cause as you probably already know the later COR pages include such functionality.
Even if the settings for two CORs are the same, remember that toll analysis links to COR.
Additionally, CORs can be used to link to...
I can confirm 100% that version 9 is required, and if you're going for version 9, request v. 9.05 which is the currently available release here in the UK.
You'll also have the capability to pursue VAL announcement boards, the new-fangled TN750C equivalent. These store up to 1 hr. of...
Guys,
Just a warning. On version 9.5, change sys feat., the DCS+ config defaults to Italian !
On a UK switch, if this goes un-noticed and is not configured by someone, if someone tries to remove call forward from an off-net extension, the control element will lock up.
This causes every...
Hi Europe,
DNA is somthing we definitely want to investigate, yes.
I hear that Avaya Provision is more useful still, allowing PBX configs to be copied to a standard Wintel box, then back again etc.
Sounds very useful when working with lots of PBXes.
Cheers,
Giles.
ghowson -
Nice to see someone promoting Linux.
It should be easy to use Linux with the free method.
Just get hold of a Linux-based Procomm or Hyperterminal clone.
As for analysis, personally I use Excel, but I'm sure someone must have developed a Linux-based equilavent. Probably better too !
Roche - Thank you very much for that. I will be sure to post any improvements. It's great to have an open forum.
JT - You are correct - IP soft-phone and IP hard-phone are customer-options on the Definity. No adjunts are required. Only Lucent (and if you're running code version < 6)...
Perhaps this is restricted. Correct me if I'm wrong here, Chris, but I know it's possible to "cha perm login"; a lot of restriction can be placed upon particular user-ids.
Leading on from what you were saying, Chris, about "The default is to leave the call bridged on the phone...
It is very difficult to provide acurate costs for code-version upgrades since Avaya bases its pricing on your current system, taking into consideration RTUs, customer options, ports etc.
We paid 33 k. USD for the upgrade of two G3Si PABXes; details follow -
(1) ECS; G3Si; DCS+; EAS; 1000...
Doesn't sound too hot, although preferable to serial or dial in over an analogue line.
Has anyone tried checking the response times for a ping -t from a DOS prompt ?
Traceroute may be of use of you're remote.