Hi All,
I have a MiVO 250 (6.2 SP1) and a custom SIP application that needs to call the local users and also needs to call PSTN numbers. The SIP application is connected to the system using SIP trunks and I have no problem calling the local extensions or the local extensions calling the...
@kwbmitel - only comment is you no longer have a uniform dialing plan and it may require ARS changes in the cluster for RDN routing unless your using unknown number of digits to follow.
KwbMitel is correct, hunt groups will work. O course you have to manage multiple number this way.
Another way would be to add more multi-line appearances of the number to the device, down side of this method is the queue depth is limited to the number of keys programmed. Upside, only one...
@brewski6666, Configure the DID's in the DID to terminate on the user (your current speedcall will work too, but the DID table is a much nicer implementation in my opinion . As kwbmitel says, make sure the campon is enabled. Configure the call coverage announcements for the desired RAD...
Check the recall timers on system B, sounds like it is recalling to nupoint before cfna timer expires on system C. The recall timer will be running on system B, as this is where the transfer is being performed
...Destination Number (internal Directory Number or any other termination point) to which the DID Number will be redirected. Valid digits are: 0-9, *, and #.".
But this is incorrect the destination does not need to be unique. The form will take the same destination for multiple DID's and...
In the SIP Device Caps - Signalling and Header Manipulation - Allow Display Updates - set to yes.
From the help: "Select Yes to allow the system to update SIP phone displays with connected party name and number information during transfers, conferences, and call forwarding scenarios."
This may...
Do a wireshark trace, if you see MCD sending a 180 to the Mediatrix then the problem is with Mediatrix, Also, check MOL for the config guide, believe you are looking for doc: 08-5159-00011
Jexter,
62038022 is the called number and you said the extensions are 3 digits in length. If this is the case then absorbing 5 digits will leave you with 022. Is this a valid DN in the system? Meaning, is 022 a valid extension number? If not then you should have a speedcall that translates...
Jexter,
Can I assume this is the call that no longer works?
13:53:20 RI23 DPN 1A ISRM_I ;10;*3#*233*`IBc#*58*CI*W6a#
13:53:20 RI23 DPN 1D SSRM_I *50*000061429057232#62038055
13:53:20 RO23 DPN 2 CRM/CIM ;0;
The incoming number being dialled is 62038055 - the trunk attributes (trunk service...
...solve the issue, you need to know what signaling Allstream is sending. Are they sending a 183 or 180? If you inspect the CCS trace you may see a *240 indicating a progress is being received, if this is being received and the audio is not being cut through try turning on the ccs feature...