Oracle would like to EOL Res3700 but with such a big installed base it's not so easy. They are coming out with a Simphony-lite type product and hoping that takes over the restaurant market but as of now no plans to end Res. What does end is Win7 Pro, next January, and Win7 embedded 1 year...
The Win8.1 WS6's are 32 bit hardware and will never take a 64 bit o/s load. They never made a Win10 image for that hardware, they updated the guts of it to 64 bit and did a Win10 version. They still sell the Win8.1 32 bit model also because a lot of Simphony customers have still not upgraded...
Final bios is Q2012F which someone just posted on this board. There should be a version that runs from a thumb drive, or else take the files and put them on the root of the cf and reboot, then remove them from it after the update runs. Shouldn't have to remove doc or anything like was suggested.
Micros used to sell a kit for this, the hdd mounted to the back of the lcd, I suppose you could use duct tape in a pinch :^). Sata cable was standard but power was custom, not sure how you would sub for that. They had a POSReady 2009 and a POSReady7 image for them.
Oracle E7 release 4.2 was broken and caused major customer issues, probably why upgrades were halted. 4.4.2.1 was released a few weeks ago and fixes the issues. I would get a standalone reader from your cc processor and then figure out what you want to do long term.
Sorry I don't know but I will say after reading about 50 posts here today that when people ask for help with Micros it would be a good idea to give version of Res, type of WS (4/4LX/5/5a/6) and any other relevant info. It makes coming up with answers more likely.
The WS4/4LX power supplies fry because they are all 12+ years old at this point. I have a customer who insists on keeping his 4LX's running, constantly spending to fix them but can't get parts. All I have for parts are 12+ year old pulls which later die because they already ran for years in...
Can you confidence test from micros utilities? If so you have a software not hw problem.
This trick worked with a similar issue at some sites in the past, assuming you are dealing with WS4/5/5a not WS6:
On the WS where printing fails, rename the SYShardwaresetup.dll to .old and re-cal the...
If it's real old/been in the kitchen a long time the mech inside can get gummed up and just stop/jam. You either have to get a tech to take it apart and clean it or just replace it.
Turn it off, hold the feed button and turn it on, keep holding the button until it starts printing. After...
Going from 4.x to 5.6 or higher does require preconvert, not sure why it would fail if you have done that step. I've seen the same issue but it was due to not running preconvert.
Can you hit the winkey to get the start menu, then get to control panel? From there:
Save Settings Icon, Default settings tab, check the reset box and hit ok.
This is like doing a wcf on a ws4/5
I have used the Oracle images to repair units, they work. I don't know of any way to use a custom image - I tried some various imaging software without success but one customer of mine claims to be doing just that using Macrium software.
mxap,
Glad you figured it out, been a few years since I played with that config and I remember it was fussy. Sorry I'm not in here very often to answer questions. I found one other reg key dword to add, per some older instructions, not sure if it's necessary but here it is...
NOTES:
1) TM88- serial interface.
2) Setup OPOS printer in Epson
3) Setup OPOS cash drawer in Epson - LDN needs to be
"HydraCashDrawer1" <---case sensitive
4) DO NOT use OPOS printer in MICROS, set it up as a regular old
Micros TM88 w/serial Interface
5) Add cash drawer in WS > Peripherals, with...
The Oracle 720 is a DT Research DT317BT, the 721 is a DT317CR. You could maybe find a distributor to sell you the DT tablet for less. Any Windows device can theoretically work with Res but making everything work is the trick.
It's a common problem with the WS5 and I don't know of a permanent fix. I usually try two things:
1. power drain - disconnect power and all other cables, wait a few minutes, reconnect and reboot
if that doesn't work, try again while also re-seating the cf card. If you're still stuck try:
2...