Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations SkipVought on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. mike144

    Definity PRI ed to Magix help

    I have a Magix with PRI to a Definity. I can call from the Definity to the Magix. When I call from the Magix to the Definity, I see the display on the definity phone, but does not ring the definity phone. I can pick up the call and it stays up but can not talk in either direction? any ideas?
  2. mike144

    Routing and Extension to ring at a networked site?

    I have a Magix with PRI to a Definity. I can call from the Definity to the Magix. When I call from the Magix to the Definity, I see the display on the definity phone, but does not ring the definity phone. I can pick up the call and it stays up but can not talk in either direction? any ideas?
  3. mike144

    Intuity LXI

    not to much you can purchase form Avaya RTU under 2500. I would say yes...
  4. mike144

    Number of connection

    Avaya has told us that only 5 can log in at same time with same login on SI and it cant be changed. We have run into locking up ports and cant get in till we reset. Avaya has told us that is because we were Xing out of ASA not loging off first, closing then disconnecting. This has cleaned up...
  5. mike144

    How to shield the calling number when I use EC500?

    I think its "ch xmob conf set 1" change calling number type to PBX. If that wont work,"ch isdn network" give a name like stripSDN type is 3 leave coding blank. make new route pattern for EC500 calls use stripSDN in the Service\Feature field. this will strip everything. You may already have...
  6. mike144

    Speech Access IP connect

    Have a Speech Access Server that is IP connected to a S8500. All is running but when the Speech Access Server requests Medpro resources non are available. The IP phones work fine in the system.Its a flat network, have rechecked config note 3900, but no luck.
  7. mike144

    Bridged Call appearance

    you need at least two call app of the remote phone, the 1st and 2nd button to do it without manualy choosing the main phones own call app button to transfer.
  8. mike144

    Intuity LXI

    Yes, that is correct. If you look at the second page of your vm hunt group, you can see "Calling Party Number to Intuity". When thats stroked Y, and the Green Feature is on in the intuity, Caller ID goes to the intuity..
  9. mike144

    Denial Event 1220 Question

    are they IP, if so on the signal group form make"calls share ip signaling connection" yes.
  10. mike144

    Sets dropping from Legend

    I also had same issue, we changed the wiring from 2 pair to 4 and resolved issue, found it in old manuals.
  11. mike144

    Moving MedPro

    in 2.0 think you just have to disable the ip-interface, than remove it, change the slot and reinstall for that board.
  12. mike144

    Intuity R5

    you can use auto att routing.
  13. mike144

    ec500 query

    do you have TN2182B,s in PPN and EPN's?
  14. mike144

    AT&T Pt to Pt T-1 (DS-0 CH 24 as a 64K data Ckt)

    I think you just need to set the Point to Point to PRI with DCS.
  15. mike144

    How do you DCS two Definities via DS1?

    Main switch (example) trunk group 1 -Group type:tie -TAC:204 -Comm Type:avd -Trunk Type:wink/wink -Used for DCS?yes PBX ID:2 -Put in members 1 thru 22(NO MORE) trunk group 2 -Group type:tie -TAC:205 -Comm Type:data -Trunk Type:wink/wink -put in channel 23 (ONLY CH 23)single member data mod...
  16. mike144

    PBX/Intuity DCIU link cabling

    isolation Data Interface unit, com code 107422735, should be able to get from Avaya Supplier, you need the two cables that connect to it also. If this is a release 6 or below, you need a processor interface carde also.
  17. mike144

    s8300 Announcements

    dont think you need any hardware, you may need software.
  18. mike144

    s8300 Announcements

    yes, believe we used val manager, the IP of the processor and port 23 to access
  19. mike144

    Saving Announcements

    oh, look at the data mode, its say port 02a02 not 02a04, the board location? could this be it
  20. mike144

    Saving Announcements

    have you tried "save ann spe-b remov 02a04" Saving to removable-meadia?? or are you trying to save to hard drive?

Part and Inventory Search

Back
Top