Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: cpm23
  • Order by date
  1. cpm23

    Dchannel Daughterboard on Dual loop PRI

    Thanks everyone. Switch 8 on SW 3 was wrong. Changed it and it popped right up.
  2. cpm23

    Dchannel Daughterboard on Dual loop PRI

    Is there a chance the switch will INI if I try an FDL and the dip switch is set wrong?
  3. cpm23

    Dchannel Daughterboard on Dual loop PRI

    No, I did not do an FDL. I'm wondering if perhaps the guy on site has the dip switch set wrong on the dual loop card.
  4. cpm23

    Dchannel Daughterboard on Dual loop PRI

    I have a point to point T1 between an Option 11C and an Option 81C. The 81C has a dual loop PRI card on loop 116 w/ a Dchannel dauterboard on it. I tried bringing it up but the Dchannel won't come up. I got this on the 81C side when I tried to enable the MSDL: .enl msdl 8 GROUP 3 MSDL108 GROUP...
  5. cpm23

    Can not dial out on PRI

    Thanks to everyone that replied. The provider had to change the Dchannel protocol to DMS100 to get it to work. I don't know why. I've been able to use ESS5 many times before.
  6. cpm23

    Can not dial out on PRI

    No to both questions. I have tried using LD 36 thru the maintenance set and by using the ACOD. The provider is in the process of changing the protocol to DMS100. Hopefully that'll do it. Thanks for your response.
  7. cpm23

    Can not dial out on PRI

    This is the FTR_DATA. Thanks. REQ: prt TYPE: ftr TYPE FTR_DATA CUST 0 TYPE FTR_DATA CUST 00 TBL **DAPC**PREFIX TABLE NO: 00 ** UNKN**INTL**NATL**ESPN**LOCL**ELOC**ECDP** UNKN* E164* 00 0 PRIV* E163* 00 0 TELX* X121* NATL* OPT AHD BIND BIXA BLA CFF CFRA COX CPA CTA...
  8. cpm23

    Can not dial out on PRI

    Thanks, but NPAs don't work either. Same incoming message from the CO. I changed the DMI to INTL in response to an earlier reply from M1spezi in this forum. I've tried NXX as well. I have also tried it without a DMI table. You're right about the FCAS table, but the routing was built already.
  9. cpm23

    Can not dial out on PRI

    Dchannel programming: ADAN DCH 6 CTYP TMDI CARD 01 PORT 1 DES Verizon USR PRI DCHL 1 OTBF 32 PARM RS232 DTE DRAT 64KC CLOK EXT IFC ESS5 SIDE USR CNEG 1 RLS ID 1 RCAP ND2 MBGA NO OVLR NO OVLS NO T200 3 T203 10 N200 3 N201 260 K 7 Thanks...
  10. cpm23

    Can not dial out on PRI

    Unfortunately, no change.
  11. cpm23

    Can not dial out on PRI

    ...VOD PTYP PRI AUTO NO DNIS NO DCDR NO ICOG IAO RANX NO SRCH RRB TRMB YES STEP ACOD 7006 TCPP NO PII NO TARG CLEN 1 BILN NO OABS INST IDC NO DCNO 0 * NDNO 0 DEXT NO ICIS YES TIMR ICF 512 OGF 512 EOD 13952 NRD 10112 DDL 70 ODT 4096 RGV 640 FLH 510...
  12. cpm23

    Can not dial out on PRI

    I have a new PRI that I can not dial out on. Below is what I get when I turn on Dchannel messaging (I Xed out the last four digits). The guy at the CO says I need to send E164, not E163. I have tried putting a DMI in the RLI to change the call type, but it stays the same no matter what I put at...
  13. cpm23

    Opt61C Column addition

    If you have to, and it hasn't already been done, you could add the IPE's as the second shelf of your existing superloops. For example, superloop 4 shelf 1, superloop 20 shelf 1.....
  14. cpm23

    Does IDC take DNIS (IDGT) entry of 10 or more digits?

    The IDC table looks at the called number field, not the calling number field, so you can't redirect calls based on the number the person is calling from.
  15. cpm23

    DSS 9000 BLF Direct Station Select Busy Lamp Field

    Actually, only about 120. It's the only DSS I've ever put on a 2250 and I put it in about 8 or 10 years ago.
  16. cpm23

    DSS 9000 BLF Direct Station Select Busy Lamp Field

    I called the attendant and she said the model was a DSS-9000.
  17. cpm23

    Mailbox says "No messages to review"

    Ken,you're correct. I ended up changing his password after looking over the user guide and it worked. Thanks for the response.
  18. cpm23

    Mailbox says "No messages to review"

    Forgot to mention that it is an Aria 250.
  19. cpm23

    Mailbox says "No messages to review"

    I have a user that when logging into his mailbox gets "You have no messages to review. Press 1 to disconnect, press 2 to send a message." If I press any other key it says "you have pressed an incorrect key.I ran a report on his mailbox and there are 7 new messages in it. I tried changing the COS...
  20. cpm23

    DSS 9000 BLF Direct Station Select Busy Lamp Field

    Take a look at this in LD 15 under ATT data: LFTN l s c u Lamp Field array Terminal Number LFFD x00...x00 First Directory Number of lamp field array

Part and Inventory Search

Back
Top