Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations SkipVought on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: krish8987
  • Order by date
  1. krish8987

    500 Sets/Faxes - Not able to send but can receive

    Thers is a CLS for fax services to be enabled on the 500 sets ... Cant remember the exact one .. jus check the DOC... THanks
  2. krish8987

    Incoming indicator light on and no dial tone

    Yeah i do belive in firmware upgrae.. Else the other suggestion is try to re-create those TN's
  3. krish8987

    Dialing Agent id (DN)

    Yes it is possilbe.U have to give and Phantom DN as 1234 while creating the user in SCCS.This will appear while creating the user below the agent login ID.And create one phantom DN as 1234 in M1 (say type as 500)and set the FTR as CFW 16. This will allow to reach the agent by dialling 1234...
  4. krish8987

    Telnet via Ethernet on 11C

    hi salo, confiure your ethernet and PTY ports as said in above.. and connect your switch to any port of your data switch,. Then u have to telnet to the data switch and after login there u do a rlogin xxx.xxx.xxx.xxx.(Ip address u assigned to our 11c)it will enter in to the PDT mode. Hope u...
  5. krish8987

    GRTD Login failure

    Seems to be quite new.. anyway thanks for updation...
  6. krish8987

    Making NCOS

    While u create now NCOS you have to map those NCOS to FRL's in ld 87 under NCTL prompt.Under there prompt u have to give the NRAG (will be 0,1,2,3,etc) and for each NRANG u have to assin an FRL vaule.Usually do one to one mapping. Say if you NCOS is 0 say FRL as 0 and so on. Also in RDB under...
  7. krish8987

    GRTD Login failure

    Confirm the version compatibility with SCCS 4.2. And u have to close the Report listener which will run normally on your system.And if u have SCCS client installed already jus check with u can able to login thru that to SCCS.And the login ID you are trying to login should have minimum access as...
  8. krish8987

    Symposium Sybase installation errors

    Pls make sure only u have the win2000 and proper drivers for ethernet and Tape drivers if any installed.Dont allow the junk like disk manager and rest which will the server personals likely to intall to monitor the server performance.It is as easy is installing the 4.2.But u have to wait even...
  9. krish8987

    Making NCOS

    1.first make your MAXT value to 5 in your FTR data ( u have to use LD 15 to change the value). 2.Then come and create the CRNO as o and to the INIT prompt say Deny.This will makes the route selection invalid if they dial any digit. 3.Then u can make the next CRNO entry with INIT as ALOW and DENY...
  10. krish8987

    Personal (Phantom ) Dn

    hey check the following. 1.Login to SCCS with the ID you configured for that user who is having the Phntom DN as 3456. 2.Then go to M1 and check the TN 65 0 (which is created as 3456) and check for the CFW is set as CFW XXXX (Where XXXX is the SCR number configured in the phoneset he logged IN)...
  11. krish8987

    Meridian Mail

    Hey login to the tools menu There you can find an option to get all the RLS and full system details. Thanks V.Venkatesh.