Does anyone know if there are any issued going from MICS 6.1 NA to 7.1XC. They currently have 1- 6 port fiber expansion and will be adding a secon e6-port expansion. Can I simply power down and change the software cartridge as 6.1 is actually 7.0?
I have 3 bcm systems networked using centralized vmail. site "A" is a 400, site "B" and "C" are 50's. A call is parked at site A and they page to site "B" for someone to pick that call up. Does anyone know how to set this up, I've tried setting up different routes and destination codes. ??
I recently had this exact problem, it was happening for 2 weeks intermitently and the customer was rebooting the CP150 and finally it just would not come up. It was on a MICS6.1 and The verdict from Nortel was that something in the CP is causing the software corruption until it was totally...
It depends on what the carrier has configured, normally it is either DMS100 or NI-2 and B-channel selection is always opposite of the carrier, usually descending.
The module will disable when you make the changes.
The BCM 400 is a stable platform but; Our company is nation wide with ALL our BCM techs certified and trained and we are experiencing alot of little issues with the 4.0.
One case I now have open with Nortel, the 2nd level engineer agrees that there is a problem and design has rejected his...
I would try to upgrade them to BCM 400 or a 50 depending on the number of sets needed and use I.P sets over a wireless link to the main site. And since they don't want to run a cable between the 2 buildings, they are likely going to be using a wireless solution for their data network. 200 meters...
I have a MICS 7.1 XC with analog trunks, one programmed for DISA. The system answers the line but does not send any stuttered dial tone. The same setup works fine on a 4.1 version. Anyone run into this problem?
I have a customer who wants callers to call in and be conferenced into a set in the board room. Does anyone know of a way to do this using the "NEWCALL" feature. They do not want to call each person, they want the parties to call in like they do on a conference bridge.
Put a monitor on the bcm and power it up, if you find boot error messages it is probably the BFT or worse the IDE controller. If you get no OS found the hard disk needs to be replaced or re-imaged.
I have a 400 running 4.0 with 2 PRI circuits. If i program the "send name display" in telephony resources for 1 or both PRI, both the extexsion name and company name are displayed at the called party destination. Once I uncheck send name display, only the number is sent with no company name. We...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.