  1. Chris78

    0516-862 mkvg: Unable to create volume group

    Eugene, are you able to do a dd (read) command on the rhdisk such as : dd if=/dev/rhdiskXX of=/dev/null bs=512 count=10000 if errors exists, you've got another problem Chris
  2. Chris78

    EMC Dial Home Log

    Hi driddickemc, under ECC 5.2 in the alert def policy, you can enabled the call-home alert. Chris
  3. Chris78

    Queue Depth & Winderz

    hi breslau, it depends on which hba you used, for instance on emulex, you can set the queuedepth using elxcfg (in scsi mini port), see http://www.emulex.com/ts/docfc/winnt4port/4221a8/introconfig.htm hope it can help you. Chris
  4. Chris78

    New to AIX

    Hi Driddickemc, Chacalinc is right, try 'lscfg -vl fcsX' for each of your adapters in order to see the WWN (must be Z8) and the firmware (must be Z9). Hope it can help you Chris
  5. Chris78

    Symbol is not exported from unix

    I am trying to run a Oracle Agent from ECC 5.2 The app doesn't run and complains that a set of symbols are not exported from "/unix". Actually these symbols are defined (as seen in dump -Tv output) in shr.o module in /unix. exec(): 0509-036 Cannot load program...
  6. Chris78

    DS-16B2 switch failed

    Hi, The solution was to swap the DS-16B2 switch then on the new one, the upgrade from 3.1.2a to 3.1.3 has worked fine. Christian
  7. Chris78

    Cannot see the Symmetrix (DMX)

    ok, So think you must in FC-SW protocol, means that the VCM bit must be set on the FA connected to your host ; so it means that you must at least see a little device named 'vcm' which is write-disabled. Other thing to check on your host side : -I suppose that you must have a LP9xxx hba so you...
  8. Chris78

    Cannot see the Symmetrix (DMX)

    Hi TekieMDX, Which license are set under Solution Enabler 5.4 ? (check the symapi_licenses.dat) The server where you run the command is attached to this DMX box ? throught a switch ? (if yes, zoning switch is ok and activated ? are there some gk configured too ? what is the result of a "symcfg...
  9. Chris78

    DS-16B2 switch failed

    Hi folks, I'm trying to upgrade a DS-16B2 switch from 3.1.2a to 3.1.3 but I've still have the same error message "writing flash 0 ................tslog is not initialised, use tsLogInit to initialise." then it reboot with a recover process back to 3.1.2a. Any idea ? TIA Christian
  10. Chris78

    What to do after creating new EMC device

    Hi hugonovo, What Chacalinc said is right, if you want to be able to see new device without reboot, complete every target from 1 to 255 and luns from 0 to 255 ; btw if your Sun server got the latest generation of fiber hba (leadvill driver) you can add news devices without reboot and without...
  11. Chris78

    ECCOE 5.1.1 upgrade to 5.1.2 known issues or helpful tips

    Hi Coolice, Describe your configuration (how many AIX, Sun, HP servers with symmetrix agents, host agent, master agent, etc...) Christian
  12. Chris78

    Configuring old Symmetrix 3930

    Hi Schweigstill, Chacalinc is right, there is a lot of action to do !! which microcode is it ? how many SA / FA do you have ? which protocol on FA ? volume mapped on SA / FA ? masking to do... Christian
  13. Chris78

    How Can I increase the size of meta volume online?

    Hi Amins, In fact, you can increase a meta-volume under Win2K or Win2K3, the only problem is this process is only supported in 68 (the top level) and not supported in the last microcode (69 and 70 for DMX). In summary (because, it's a little bit long process :-) you must have a BCV meta which...
  14. Chris78

    HBAnyware

    Ok test done VBit on = HBAnyware show some LUN 16XXX VBit off = HBAnyware show normal LUN X Thanks for your answer Christian
  15. Chris78

    HBAnyware

    Hi Chacalinc and thanks for the feed-back, In fact, we got this situation since the begining of the installation. The configuration is as follow : Symmetrix #xxxx | | FA-WW-port X FA-YY-port Z | | DS16B...
  16. Chris78

    HBAnyware

    I got a very strange issue, On a Windows2000 SP3 with LP9002L-E (driver 2.21a7 + firmware 3.90a7) with Powerpath 3.0.5, we have some ghost luns under HBAnyware (luns 16384, 16386, 16391, 16392, 16393, 16394, 16395, 16396, 16397, 16398, 16399, 16504, 16505, 16506, 16507) !!! Any ideas would be...
  17. Chris78

    Clariion FC4700 shared disk space

    Hi fromans4, under MSCS, either node1 or node2 will see the luns but not both in the same time, it's working as design (passive - active for each luns which are set in the MSCS config, I mean in each group set under MSCS GUI). The only way to see the same luns from 2 Win2K servers and more is...
  18. Chris78

    lpfc0 & 1 changes to lpfc2 & 3 after firmware upgrade

    Hi, Thanks for your update Chacalin, you answered more quickly than me! Cheers Chris
  19. Chris78

    Protected BCV's

    Mendolia, A BCV can be mirrored, it can be the last chance to keep safe data by running some reverse split. Remember that the BCV M2 is not seen by the host. Christian
  20. Chris78

    Assistance Configuring Fibre Symmetrix Needed

    Hi Gotraidbox, Don't forget to use the elxcfg.exe tool provide with the Emulex driver. elxcfg.exe and HBAnyware.exe are in the "Emlxapps200a2.zip" file which is contain in the "port-5-2.21a7-2b.zip" file which is available on the Emulex web site at : http://www.emulex.com/ts/docoem/framemc.htm...