If you are generating a SIP 403 error that means you are receiving a number that your equipment doesn't understand, try looking at your configured dial patterns.
Hi, this is a known issue on Rls6 we are currently having it on two different sites with different customers. It seems that this has only become apparent since the last SU and Deplist update on Jan 18 2011.
This is Avaya's response....
Problem : Suppose file "mgcdb.xml" is somehow lost from...
What are you trying to install, the Linux base should be installed from a bootable USB which you plug in the front of ther CP-MG. ALL other software must be installed via the UCM deployment manager!
Hi Guys, I was wondering if anyone else out there has had an issue with the MGU on MG1010 blowing componants, namely C12, C13 and/or L1 on the PCB. I have had three in the last 7 days!
Hey think yourself luck we bought 12 MG XPEC Cards at the begining of the year, out of 12 we had 2 with duplicate MAC addresses, 3 with non-production firmware loaded on them and 1 with corrupt firmware. Since the buy out by Avaya the Nortel QA has gone south big time!
IPSec should be disabled in most cases.
I too had your fault, and they way I cleared it was to carryout the Reg ucmsecurity system command, then redistrubute the token. I then deleted the node and rebuilt it.....it then sync fine and has been good ever since.
Also remember that the Patch Libary is a finite size, approx 1GB, if you already have a number of DepLists loaded you will get the error as indicated. You must remove the old Deplists first before you can load anymore.....an undocumented feature!
This is the response I got from Nortel when I asked for an update to a Business Critical Case I opened 8 weeks ago.
............................................................
MPLR29758 causing HIGH Call Reg Usage'.
This problem is over 19 years old.
It was first reported in...
Read it very carefully as not all SIP Providers are accredited for use in the CS1K environment. The reason I say this is that we made this very same mistake and are now paying for it as our provider is not recognized by AvayaN and we have issues in regards to the compatibility of various...
You'll get the "Emergency Account" warning if you are experiencing network issues as well, or if your Primary UCM Controller has high memory utilization. Try logging into you Prime UCM with the Nortel login account ID and typing the "TOP" command, my guess is you'll see lots of CPU usage.
I suggest you refer the the NTP NN43041-320_01.01_IC for the correct procedures on installing this, the document can be downloaded from the www.nortel.com
Hi guys I am having an issue in regards to incoming external Faxes via SIP Trunks, basically it appears that G711 pass through does not work, the CS1K keeps trying to re-negotiate it as T38, and the Fax fails. Not surprisingly our provider has just told us that they do not fully support T.38...