Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations SkipVought on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. NavinB

    Clearing a log file

    You can just use the command >filename to empty it.
  2. NavinB

    Interpreting Solaris Memory BANK TABLE

    Hi, I also have Sun V210 server and this is the prtdiag output:- ============================ Memory Configuration ============================ Segment Table: ----------------------------------------------------------------------- Base Address Size Interleave Factor Contains...
  3. NavinB

    Not able to login - Kerberos error

    Ya I did.....load recommended cluster patch
  4. NavinB

    Not able to login - Kerberos error

    Thanx...I too had a look for this bug but they don't have a workaround..... This is a newly built server ...so I can build it again....
  5. NavinB

    Not able to login - Kerberos error

    Hi, I am getting this error message on my Sun V210 server running Solaris 5.10 sshd[8980]: Kerberos mechanism library initialization error: unknown error. Apr 11 16:45:54 neoss03-th sshd[8980]: libpkcs11: /usr/lib/security/pkcs11_softtoken.so unexpected failure in ELF signature verification...
  6. NavinB

    Single hostname with different FQDN

    One question pops in my mind :- What should the hostname.interface1/nodename file contain myserver or myserver.mgmt.st.com ?? Also what should be in hostname.interface2 ?
  7. NavinB

    Single hostname with different FQDN

    Thanx for the info.....I'll try this out then....
  8. NavinB

    Single hostname with different FQDN

    Hi, I have two network interfaces on one of the Sun server.Can I use a single hostname with different FQDN denoting which network they are attached to. For eg Hostname=myserver N/W int 1- myserver.app.st.com N/W int 2- myserver.mgmt.st.com
  9. NavinB

    Exceed ?

    Hi, See if u find this helpful:- http://cds.dl.ac.uk/cds/interface_and_utilities/xwindows.html
  10. NavinB

    Server at OK prompt

    Thank u all for replying...I think it may be becoz of human error (power cable or power button of the server may have been fiddled with )....
  11. NavinB

    Server at OK prompt

    Hey, I read the man page of power.conf and according to the man page, the default setting is no automatic shutdown....So any more ideas ???
  12. NavinB

    Server at OK prompt

    No there was no message in /var/adm/messages ......
  13. NavinB

    Server at OK prompt

    Hi, On Monday morning, I was not able to connect to two of our recently configured Sun 280 servers.The servers were at OK prompt.I checked the message after booting it and there was no error message nor any shutdown message.Can it be due to power management settings????What to check in case it...
  14. NavinB

    Solaris 9 installation - Error message

    Hi, Your solution kind of helped me solve the problem.I found out that there was no disk in the server. Thanx !!!
  15. NavinB

    Solaris 9 installation - Error message

    Hi, I am installing solaris 9 on Sun 280R (new installation on old box) using DVD-ROM.After I give all the system configuration information it waits at "system being initialized" and afterwards it throws this error message "InvocationTargetException" and comes out.I tried booting from jumpstart...
  16. NavinB

    SSH - Password-less login

    Hi, Do the following settings :- Create a file .shosts in user's home directory having entries as shown:- other_server userid Create a dir .ssh in user's home directory having following files: id_rsa.pub id_rsa authorized_keys Similarly create a file .shosts and dir .ssh on other server...
  17. NavinB

    Legato Networker Error (I/O)

    Thanx.... The prob is solved now but am still wondering what is the real solution?? I was earlier giving nsrjb -HE followed by nsrjb -I and it didn't work. But when I gave nsrjb -Hv followed by nsrjb -Iv,it worked. Any difference between the two(The -E option is used when you are manually...
  18. NavinB

    Legato Networker Error (I/O)

    Thanx for the suggestion..but my prob is that the drive is at the datacenter in some other country and I don't have access to that.Is there any command(in Netwoker) that I can run to see the status or correct the prob ???
  19. NavinB

    Legato Networker Error (I/O)

    Hi, I am new to Legato Networker and am facing some problem in that(using SUN StorEdge L8 Auto loader).Every week we change the tapes and perform an inventory on the jukebox’s contents.But yesterday before I could do the inventory,the backup started and returned an error:- "savepnpc: error, no...
  20. NavinB

    SSH - Password-less login

    Thanks for the info... I tried using both interactive and cmd line of ssh-keygens but still the prob was the same. Ultimately, I found out that an entry has to be made in sshd_config file RhostsRSAAuthentication yes HostbasedAuthentication yes and few others as well....

Part and Inventory Search

Back
Top