Thanks lopes, what do you mean by LEC?
Do you recommend IPSI instead of tone-clocks? We are at CM2.2 hence the IP connect is not possible. What about the signalling over the IPSI IP Link?
Please advise
We have a vague requirement, the customer has a IP PBX ( Some third Party), he wants our CM to receive the voice call & forward the same using VoIP over public internet to an IP Address.
Is it possible?
Try this in the vector
Converse on skill 90 pri m passing ani and none
the above will pass ani to the IVR application, on the IVR side you need to catch these digits using a DTMF Block
Actually we are experiencing these problems from tha day one, specially during the peak times.
Data traffic is also run over the link in addition to voice.
We have Remote G650 ( critical reliable) media gateway connected thru DS1C converter complex ( Not IPSI Controlled) . At Peak Times the Media gateway keeps resetting again & again,logging out all CSRs. Another issues faced are silent calls, drop calls etc. We have already checked the Blocking in...
Actually we had replaced all key hardware & important boards yesterday.Yet today again Two PNs went down at the same time.
Now we strongly suspect the microwave link? Is it happening due to Link? How to be certain about it?
We also noticed some ES & SES ( Error seconds & Severe Error Seconds)...
Another Thing to share with you, The DS1C link with G650 is connected thru the Microwave Link.Does the Microwave link is causing these issues?
Does Any one have any experiences with Microwave Links for remote Port Networks.
We have Remote G650 ( critical reliable) media gateway connected thru DS1C converter complex ( Not IPSI Controlled) . At Peak Times the Media gateway keeps resetting again & again,logging out all CSRs.
Another issues faced are silent calls, drop calls etc.
We have already checked the Blocking...
Many thanks for the reply, actually for us the quality of service is very imp, & you know that when u talk about quality then voip is not that reliable..also leased lines for IP & E1 are of same cost.
but good to know that with leased line the distance is not the limitation. We can go upto 3000...
Dear all,
we want to have a remote EPN (G650 Media gateway) connected to main Multi Connect Avaya CM system thru DS1 Converter (E1 leased circuit). The remote Media Gateway will be based around 3000 miles from the parent system. We are planning to have a end to end E1 leased circuit for the...
Hi,
We have around 500 incoming ISDN channels from various PRIs from multiple exchanges, these short calls are happening on almost all channels.
Facility test call will not be helpful, is there any thing else..
Hi,
We are experiencing a problem, where incoming calls are getting disconnected within 0-3 seconds. We are using TN2464 BP/CP DS1 boards, every day about 2-3% of incoming call disconnects at Agent terminals. Agent sees just a incoming number followed by the disconnection tone. The system used...