    Meridian Mail 10 Tools

    Thanks a lot, it helped me to get inside the tools, never dealt with these before, thanks!
  2. molotovich

    Meridian Mail 10 Tools

    Good day, im trying to access a MMAIL release 10, I have access to the mail screen and can modify a few parameters but I need to change the following: TN whjere the card is: for some reason it shows the card TNs that is programmed to be on the slot 8 instead of 10, I believe this is why I get...
  3. molotovich

    Help with PRIU Daughter Card

    Final words: The equipment operated Ok, the culprit was a missconnection from the side of the provider that we never noticed on the balun, once that got corrected the channels went OK. It still has the alarms but the channels are working correctly The damaged equipment were the IPO 500 unit...
  4. molotovich

    Help with PRIU Daughter Card

    This is how you set these to "out of service" (fuera de servicio) As you can see, I have only 2 channels enabled, and yet I still get that blasted alarm
  5. molotovich

    Help with PRIU Daughter Card

    Mine is an R2, I dont have that parameter, I only have 30 channels Where is it? I have E1R2
  6. molotovich

    Help with PRIU Daughter Card

    Maybe I do! but the problem is I am doing this practically "by the book" another suspect is the Balum, will change that too, thanks for the support. BTW: I didnt knew about the 4.0 release I found out last night at 11 pm :)
  7. molotovich

    Help with PRIU Daughter Card

    And yes adding a licence for 2 channels will make it 10 but you need to add the licence to the system and make sure it validates, then knock all the channel fields in the PRI config down to 10 and the alarm will go away" Nope, it is still there :( thanks for the help
  8. molotovich

    Help with PRIU Daughter Card

    Ok: problem, provider has cleared the lines, but they say they dont see the IPO at the other end, this is the startup i get from the RS232 port: CPU Board Version is: 0xD0 CPU PLD Version is: 0x17 CPUID: 0x02 Present: 0x00 Present2: 0x02 Using FPGA build 0x00000817 Programming FPGA ... FPGA...
  9. molotovich

    Help with PRIU Daughter Card

    Update: I updated the old "new" IPO 4.0 to 5.0 (26) the card started working, it gets detected as PRIU, the problem i was having yesterday after all this was that all channels appears as out of service (I suspect service provider fault, to be cleared today) Question: the Manager complains that...
  10. molotovich

    Help with PRIU Daughter Card

    Update: After some troubleshooting, I removed the expansion board of the PHONE8 card, and apparently the PRIU card is being detected, now i get errors while loading the PRIU DSP, any ideas?
  11. molotovich

    Help with PRIU Daughter Card

    For some reason, it gets detected as a DIG STA 8 st startup, attaching boot log: CPU Board Version is: 0xD0 CPU PLD Version is: 0x17 CPUID: 0x02 Present: 0x00 Present2: 0x02 Using FPGA build 0x0000005E Programming FPGA ... FPGA ID 0x01 Version 0x00 Build 0x0000005E Initialising NAND...
  12. molotovich

    BCM200 Internal Error: Unable to move backup file into candidate area

    I get this error message everytime I try to make a restore on a BCM200 R4, this BCM was restored using the BIT Tool, then we did a restore with a recent backup and SOME information was restored, we found an older backup but everytime we try to put it we get this error. Using the latest Avaya...
  13. molotovich

    Music On Hold driving me mad, CS1000 Rel 7

    Problem solved... defective DXUT... :( replaced it onsite with an old card and worked like a charm, weird thing is, I did that yesterday and didnt work. Thanks a lot for the support
  14. molotovich

    Music On Hold driving me mad, CS1000 Rel 7

    @KCFLHTK I would love to, where can I do that assignment on a rel 7? I cant see the option and in the EM the option to choose the Conference loop is grayed out I have a CP-MGS Card, with a MGSCONF and MGSTDS loop on 4 0
  15. molotovich

    Music On Hold driving me mad, CS1000 Rel 7

    @firebirdscrambler: Yes, the customer has 20 MUS CON Licenses @DFKSydney: Tried both options, and yes, the TARG was preventing the analog sets to get the ACOD. Still no Music though... Already checked the wire to the source of music, the amphenol, and replaced the DXUT card Thanks for the...
  16. molotovich

    Music On Hold driving me mad, CS1000 Rel 7

    I´m having this issue with this system, im starting to believe is a big POS, sorry, but im really desperate for help. The problem is the following: I CANT GET MOH TO WORK ON THIS THING! I have configured several MoH in the past and I just CANT SEE what am I doing wrong with this one, this is...
  17. molotovich

    Element manager on win7

    You keep this BCM upgraded all the time? Thanks a lot for sharing
  18. molotovich

    Replace MMail

    @TelecomNemo Im really vouching for your option #2, unfortunately the customer requested the ticket to be pushed until next year, just as I received the replacement cards, so there's nothing more I can do for now. Thanks a lot for your input and Tips, when we check this baby in January I will...
  19. molotovich

    Replace MMail

    If it was on my hands, I would have sold them a callpilot ages ago, unfortunately im on outsourcing, so I cant do nothing about it. And well, I spoke to my manager today and he says that if the SCSI is broken, then they will sell the upgrade to the customer. But I have to try to repair it...
  20. molotovich

    Replace MMail

    If the hard disk fails.... there will be no replacement.