Hello
Ip phones 4225 are IEEE 802.3af compliant, meaning they can be remotely powered through ethernet interface.
IEEE 802.3af is divided into 2 parts : power in data pairs and power in spare pairs.
Does phone 4225 support both powering system ?
Regards
Hello
Can someone help me with this issue :
BC 11, duplicated group switch
+/- Every ten minutes, an error appears in gjlop :
B-POS GS-M S ALARM-TYPE ALARMDATA TIME
----- ---- - ---------- --------- ----
3-0-00...
Hello
Somebody can help me ?
I would like to start CDE or another GUI through X terminal.
I get the # prompt, but I do not find how to start the Gui interface
Thanks
Regards
Rorni
Hello guys,
Recently, I get a problem to have a valid safety backup using MDDT : When starting the backup, data of lim are correctly transfered, but the ftp stops in P directory, and on different files. At this time, a popup screen appears on MDDT : Error 12031.
My pc and SAM toolbox are...
les than 11, so beter to start an full new system.
Alapi : when you add a lim on line, you must stop call logging, traffic recording and after the lim is added, you have te recreate those.
but you must also set the number plan in you new lim. for this, use command ladci to copy data from a lim...
How many lims are already installed ? If less than 11, you beter to start a new system.
Else :
- Make an inl
- Connect your lim
- load the LDT with Pu like lim 11
- copy common data
- start the lim and SFCEI
- Backup
full description in alex : "ADDITION OF LIM "
Hope this help
/rorni
Hi,
Check with command "gjlsp:print=faulty".
You should send it twice : first printout will erase the log. The second printout will give you active errors.
Post the second printout here for further analyse
Regards
/rorni
hi Lalrl,
ITNUI is not mandatory.
Acctyp is enough for :
- Outgoing calls from S0
- Incoming calls to S0 with bearer data set
- Incoming voice call is you program and set active a RDC key on dts (will route all voice calls from DTS to S0).
You need only to program ITNUI if you want to give...
...the I max of the rectifier unit (normally written on the unit) : After a power failure, the power unit will deliver his max current to charge batteries.
Take into account an efficiency of +/- 80 % for rectifier unit.
VA=55V * 15 A (example) * .80 = +/- 650 VA max per lim
Hope this help
/rorni
Hi
If you cannot use the good tip of Fidde (MD >BC10, or fax ddi range too large) , you may consider this alternative :
Set your ddi route sel D1 on 4 or 6. This will prevent rerouting on congestion ( this state should occur when fax server is down)but allowing rerouting on no answer or busy...
An other way, if all guys are in the same room is to add a phone ext 61111 (wall mounted),with diversion to voice mail and to programm a pickup group with all phones.
Hi Chris
Multiple FM won't work
BUT
If A has a div on no answer to B,
B can activate a FM on A to B (*21*A*B#)
and then activate a FM of A to C :
*21*A*C#
Also a usefull tip : If A is in FM to A, a B phone may activate a FM from A to B (*21*a*B), and B is allow to forward the call as...
Hi
A lot of thing has changed with the new "Personal number" facility.
Anyway :
Q1 : if A is diverted to B and B is follow-me (*21*C#) to C, calls to A extensions will be forwarded to C.
BUT is B is diverted to C, calls will stay on A.
I advise you to tell to secretary to activate a FM when...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.