Recent content by VDG

  1. VDG

    a question for the veterans amongst us

    I would check CM08 specificly 187 and make sure it is a 1. 187 is: Recall priority over Call Forwarding and 0 sets Recall higher. hope this helps.
  2. VDG

    DTerm IP installation

    What type of Dterm phones. The type determins what options you need to set in the DHCP Scope.
  3. VDG

    Installed PRI and need ported number to ring ATTCON

    Take a look at the ALDN command. This should do what you need.
  4. VDG

    How do I replace parameters in a SQL Query

    Well, I fianally figured out ho to get this to work. It is really quite simple and I guess I missed somthing in the docs. The SQL Parameters need to match the fields in the form that call the ".asp" file. VDG
  5. VDG

    How do I replace parameters in a SQL Query

    This is probably a newbie question but when programming in C++ I have always found it easier to dynamically create the SQL Query string rather than to use parameters. Now in MSFP I'm having troubles with both. On my page I used the MSFP Database Results Wizard and I have my parameters in the...
  6. VDG

    Activate new Line in PAM

    Are you adding Dterm (Electronic) sets or Single Line? If Single Line then yes you should have dialtone, for a Dterm set there is a little more to do. 1. The len needs to be assigned as F2101 10>0123:F2101- 2 Assign key data using command 90 9000>2101,01:2101- 3 Asing a Prime Line...
  7. VDG

    Scope issue s using TFrame

    I am working on an application that has a TFrame component and as long as I access my LoadFrame function from the frame, by a popup menu, it works fine and the images load Ok. However, if I try to load the frame from the application my private class variables are unreachable. It doesn’t matter...
  8. VDG

    Work Mode Activation

    Acording to the book that's all that is required. While testing, if the change was made to the split or login while the agent was logged in then the changes will NOT take effect until the agent logs out and back in. Victor
  9. VDG

    2400 IMX

    That's Normal. When the first LEN on that card is assigned the OPE lamp will light and the other 15 line status lamps will flash. As an aside, by first LEN I mean any one of the 16 not the bottom LEN. Victor
  10. VDG

    Work Mode Activation

    There should be a check box at the bottom of Split Data that says "Multi Work Mode", this needs to be check. Only logins with the Attribute set to a split with "Multi Work Mode" checked will be able to set Work Modes other that 1. Victor
  11. VDG

    SV7000 Configuration for SMDR

    The set up is pretty simple and is listed in the Feature Programming Manual. Hyper Terminal will not work however, as the process is a polling process (the SMDR reciving application must request SMDR records and ACK them when received.) I have 2 applications that pull SMDR records. Contact me...
  12. VDG

    VIRT PIM?

    In the Virtual PIM IP equipment may be assigned to any phisical line group, 020000-020237 & 021000-021237. The catch as I get it from NTAC is that Equipment must be the same in each line group. That means that TEC 12s can NOT be mixed with TEC 3s, just as if cards were being used. for...
  13. VDG

    neaxmail ad-40

    I don't know where the the Directorys are stored in the os2 however, try doing a control-J and enter the extension in the 'ID or Ext' field. Sounds like the extention you are trying to add matches an ID not an Extension. If this is true change the ID of the extension.
  14. VDG

    neaxmail ad-40

    Check to see if a Transaction box is setup with that #