Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations dencom on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by dnava

  1. dnava

    Loud sqeal when off hook

    These are TDM's, but I wanted to say thank you to TDMtek. even though it's been 20+ years since your MG class, your mind is just as sharp as it was back then. That was the problem. we took no chances and replaced both Per Sig cards, one in each cabinet. Thanks all for the help. Nice to know...
  2. dnava

    Loud sqeal when off hook

    On a Option 81C when I go off hook on all phones we get a loud sqeal noise. Anyone have any ideas what could cause this?
  3. dnava

    Port forward to callpilot 100/150

    DDrewsky, Thanks for the info, this is a big help.
  4. dnava

    Port forward to callpilot 100/150

    Does anyone know what port you could forward to to access the callpilot over the internet? Example of what I'm looking for would be 254.xxx.xx.12:XXXX then this forwards to an internal IP of 192.168.1.14 We would like to use this for remote programming. Thanks
  5. dnava

    How many T1's does norstar support

    6 installed systems with 2 of them coming up in less than 30 days for one year installed, says your wrong. Not bragging, just stating what is. If you look at the programming it shows that that forth one is there.
  6. dnava

    How many T1's does norstar support

    Nortel will only support 3, but it will take a 4th one. Like cook1082 said "2 in the KSU and only 1 card in a trunk mod. Except you have a total of two trunk mod's with one card each in them.
  7. dnava

    PRI's Supported

    ldutchman, Happy to talk to you about this. Send me your e-mail address so that we can set up a time to talk.
  8. dnava

    PRI's Supported

    I have 5 MICS XC systems that I have installed 4 T1 and or PRI into one system. Some all puplic some puplic with Poin to point. The longest running one was installed 10 months ago and have yet to have any problems with them.
  9. dnava

    SMDR 6 EXT to EXT

    Thanks for all the information. i thought that might be the case, but I was hoping that there might just be an alternative answer.If anyone has one I would love to hear it as I'm sure others would to.
  10. dnava

    SMDR 6 EXT to EXT

    Can the SMDR 6 give out information when you call ext to ext within the same system? If not is there a third party device that will?
  11. dnava

    Hook up a external Modem on a OPT 11

    I'm trying to hook up an external modem (US Robtics 56K Faxmodem) on a option 11 with S/W Release 2355. I have a cable that has 3 cords coming from it pluged into SLV P2. Port zero works fine for local programming. I have this modem pluged into Port 1 with the "modem eliminator" removed. Is...
  12. dnava

    Is my option 11 a Basic or Enterprise system?

    We have an option 11 that we pulled out of mothballs and wish to use it. We did a LD 22 to find out what we have, which is: Version 2111 Release 23 Issue 55 + Our question is how do we find out if the system is a Basic system or hopefully an enterprise system?
  13. dnava

    4th PRI in MICS XC 7.0

    None so far.
  14. dnava

    4th PRI in MICS XC 7.0

    To answer some questions. Yes I have installed the Trunk Modules in expansion ports 7 and 8. The ratio may seem wrong but for this customer it works just great, they use 2 PRI lines for local and long distance and the other 2 PRI's are being used on an Auto Dialer. For voice mail they are...
  15. dnava

    4th PRI in MICS XC 7.0

    I do not know if anyone has tried this, but I thought that I would, and by god it works just fine. I installed a 4th PRI card in a MICS XC 7.0 System. When I looked at the programming before I tried it, it always gave you the PRI-D option, so I installed a 2nd Trunk Module and installed it and...

Part and Inventory Search

Back
Top