  1. birdseye51

    DIUT2 Variant

    Could any one please advise what the difference is if any between the DIU T2 variant S30810-Q2226-X100 and S30810-Q2226-X200? This is to be fitted in a HiPath 4000 V6.
  2. birdseye51

    DIUT2

    Is the DIUT2 a replacement for the obsolete CDG card. If so what are the enhancements of it over the CDG? Any info on it will be much appreciated regarding its connectivity.
  3. birdseye51

    Siemens Hipath Hot desking

    I can only answer for a HiPath 4000 and the answer is YES.
  4. birdseye51

    Caller ID with Hipqth 4000

    You will not be able to display the caller's ID on analogue phones. If a name is added is AMO PERSI for an analogue phone then only when it originates a call to an Optipoint/Optiset will the name be displayed on the destination phone. It doesn't matter what type of SLMA card the extension is...
  5. birdseye51

    STATION IS UNASSIGNED OR AS AN ACD NUMBER error when setting CFU

    Further to my previous comment, that is why you can't see the station using Assistant because it's not configured. Add the station using Assistant if you are more familiar with that than using Comwin. Incidentally if you dial 2901 you will get a number unobtainable tone indicating that the...
  6. birdseye51

    STATION IS UNASSIGNED OR AS AN ACD NUMBER error when setting CFU

    Hi JNZY111 2901 has not yet been configured as an extension. The R in the WABE output means that the number has been RESERVED to be used as a station. You would first need to create the extension using AMO's SBCSU for a digital station or SCSU for analogue to assign it a port number. Once...
  7. birdseye51

    STATION IS UNASSIGNED OR AS AN ACD NUMBER error when setting CFU

    Could you verify what 2901 is configured as and show the output using the commands below. DIS-WABE:TYPE=GEN,CD=2901; DIS-WABE:TYPE=GEN,CD=2901,DPLN=0&&15;
  8. birdseye51

    callback no answer Hicom 300E and HiPath4000 v1

    Think the AMO is CTIME
  9. birdseye51

    Hipath 4000 Hold Timer

    AMO-CTIME, CP1, CTHLDREC Default is 300 secs
  10. birdseye51

    Get information about circuit on HiCom 300E

    If this is a CAS circuit then it will be configured using AMO-TACSU; If you DIS-BUEND; this will display all the trunk groups configured in the system.
  11. birdseye51

    Get information about circuit on HiCom 300E

    Use AMO TDCSU dis-tdcsu
  12. birdseye51

    V6 Crashing

    Please read details below. This has caused V6 systems to reload. “Leap second handling” on SUSE/NOVELL Enterprise Linux (SLES11) based Large Converged products Message Body: SEN LC Products based on SUSE/NOVELL Enterprise Linux (SLES11) can be affected by “leap second handling”. There is...
  13. birdseye51

    Siemens Hipath 4000v3 unable to perform trunk transfer to elastix

    It could be that the destination side is rejecting the call for some unknown reason. Don't know why given that you're able to route a call succesfully between the 2 systems. A wireshark trace would give you more visibility of what is going on and which side is rejecting the transfer. This would...
  14. birdseye51

    Siemens Hipath 4000v3 unable to perform trunk transfer to elastix

    Could you try adding TSCS to COT 101 and L3AR to COP 1