Search results for query: *

  1. mduser

    MOH FOR ACD

    In the SERV parameter the MOH is stated this settings say NO MOH !!! Settings: SERV=D1D2D3D4 D4 -> 0 = no MOH 1 = MOH is provided 2 = MOH only is user got RVA So you have to change it to 101[b][COLOR=red]1
  2. mduser

    Change the Username and password

    To jaylek, To change the MDUSER account you need to follow special instructions, as it is the default account. First you have to logon as MDUSER... Than with IOUAC:NAME=MDUSER,NNAME=NEWNAME; change the account name to something else (in this case "NEWNAME"). Than with...
  3. mduser

    Invalidation of REl

    To 73vette, If you want to unable a dump on the HDU use: FICAC:PATH=/SYSN/USRx/SES/DR/RELx,FCAT=GROUP,ACC=N; For USRx and RELx, state the proper value. It will stae dump not valid and at the next dump this one will be overwritten. If you've choosen the wrong REL you can undo this with...
  4. mduser

    Mobile Extension

    Hello LALRL, The command REEXI is used to initiate a remote extenbsion. the two types of remote extensions are defined and licensed, each one with a different level of functionality. One is called Mobile Extension (MOB) and the other is called Fixed Remote extension (FIX). Mobile extension...
  5. mduser

    How can I change the NIU EIC ?

    To MDsup, Fisrt of all I don't work (or worked) at Ericsson. I'me not even working in the MD110 environment anymore but in the AVAYA (sorry). But working with MD110 BC10 gave me a must to look into this matter. At preparing systemdumps we used a number of 1 magazines LIM's with only the...
  6. mduser

    How give priority to received calls in ACD groups?

    You can only do this by making differnt ACD groups. ACD group 1: Direct calls (high priority). ACD group 2: Diverted calls (lower priority). On the Agent position (Digital extension) make 2 ACD ADN's and put them in resp. ACD group 1 and ACD group 2. Use Multi Member Busy for blocking...
  7. mduser

    SMDR - Ring Time

    Yes, the MD110 can give you ringtime and/or abandoned calls. However it is only for BC10 / BC11 with the remark tat abandoned calls in BC10 are only in the SMDR for external incomming calls. Not for internal calls. In BC11 both are suppotrted. ou need to use the flex. formats for SMDR to see...
  8. mduser

    Traffic check on Extension

    There can only be one extension per LIM in traffic measusrement. If you want to measure two extensions you have to state them in different LIM's. Maybee you can move the second extension to another LIM. If you want to see information for a specific extension, the information in traffic...
  9. mduser

    Connect NokiaPremicell to MD110

    In the past we used the Nokia Premicell. We connected it on a TLU-75/1 to the MD110. As we don't use it anby more I can't see the route parameters (ROCAI/RODAI) anymore. It was an external route with a route access code (DEST). LCR is optional to use. At this moment we use the AS522 GSM Gateway...
  10. mduser

    DISA - Inbound call attempts disconnect

    To 73vette, When using DISA, is it the 3rd digit when dialing the authorization code or from the dialed number? Are you using Regional or central authorization code? Central autorization code: Initiated ... AUCOI:AUTH=xxx,CILCOD=xxx,CAT=xxx/CSP=xxx,CHECK=NO; After dialing DISA: * 72 *...
  11. mduser

    One paging system in 2 nodes

    If it can't be done by ISDN Qsig, can it be done over any other type of signalling (DPNSS or whatever)??
  12. mduser

    Customer Identity Request (CID) for internal calls

    To Avstral, Thanks, your solution works fine. Mduser.
  13. mduser

    call waiting analog

    Your setting of the SERV: D1D2D3D4D5D6D7D8 = 00021106 D3D4 = 02 = Open for intrusion and reception of call waiting tone from another party. D7D8 = 06 = Reception of call waiting tone from antother extension, PABX operator and external line permitted. If you also want to initiate Call waiting...
  14. mduser

    Call Diversion for Hunting Group

    In general hughsmith is right. If the group is a support group it is recommended that they are diverted to a another location if there are no members logged in any more. This could be the night announcement. However it can be that you want to divert the groupnumber to another location at...
  15. mduser

    how to initiate md -computer connection via niu-ethernet cble

    To Yazici, You said that you're able to login with SSSS without ';' to niux. In niux you can use the 'netcnf e' command to see the IP settings of the NIU board. See Example below. Maybee it will help you. (If necessary you can change the IP parameters). For more commands in niux, type help...
  16. mduser

    ALEX

    ALEX (Active Library EXchange) is the program and the database as I call it contains the data. It gives you the same as dynatext did before, but you use Internet explorer or Netscape as browser. So it's much user freindly than the former Dynatext. The database itself is a *.alx file. But if...
  17. mduser

    SEARCHING DYNATEXT SOFTWARE

    The Ericsson InfoChannel is a closed community. You need a Username / Password. I do'n know what it is so I can't haelp you with that, but this is the URL: https://infochannel.ericsson.net
  18. mduser

    ALEX

    The cost for ALEX was ~600 Euro for the ALEX Tool with the BC11 database. There are different databases for the different Md110 releases. I know that there are databases for BC8, BC9, BC10 and BC11. If the old databases can still be ordered and/or there is a price difference between them I...
  19. mduser

    ALEX

    I purchased ALEX without a necessary training cource so I know its not necessary to do a cource before purchasing. I think it's depending on where you buy it from. Most distributers are affraid that you use commands that can screw up the exchange, that's why they're affraid to sell ALEX, as it...
  20. mduser

    Call Diversion for Hunting Group

    A master extension is an extension which is permitted to order group do not disturb, bypass of an extension with group do not disturb activated or follow me for an internal group hunting group by dialling predefined procedures. So initiate the master extension by using SPEXI:DIR=xxx,OPT=M...