Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Ruuvan

    Emergency Call - drop in progress calls to get a line.

    Pretty sure the only workable solution would be to program the Call Steal function: steal the call from a user, then drop it to free up the line for an emergency call. I don't believe there is a way to force drop a call on another extension.
  2. Ruuvan

    Disconnect Clear Time

    Hi Avalon, We sometimes get the same problem with analogue aux groups. As long as BT have definitely set it to 500ms at the exchange, we have our systems set to 120ms (Line > Analogue Options > Disconnect Clear) and this seems to resolve the issue. Try changing your IPO to this and, if it...
  3. Ruuvan

    IP9608 - Connection Issues

    Hello all, Thank you all again for your help. We rebooted the CCU on Friday and the phones are coming up today. I can only assume the changes made by the IT company have worked and a reboot was needed for the system to see it? Anyway; thanks again!
  4. Ruuvan

    IP9608 - Connection Issues

    RE Stun; it is configured and goes out on port 3478. Returns the correct WAN IP so it would appear that's all set up correctly?
  5. Ruuvan

    IP9608 - Connection Issues

    Thank you, nnaarrnn. I will give this a try; though it is not something I've done before I have read up on the how. Thank you again to everyone for your responses.
  6. Ruuvan

    IP9608 - Connection Issues

    UDP port 1720 is now removed. Everything else still in place port-wise. All H323 inspection is turned off on the device. Still getting the same thing on Monitor. Model of Cisco equipment (in case it helps!); ASA Version 8.2(1) Device manager 6.2(3) Hardware ASA 5505
  7. Ruuvan

    IP9608 - Connection Issues

    Thank you, Gunnaro. I've got a list of what they've set up, doesn't appear to match up with what I asked for! UDP 49152-53247 UDP 1718 UDP 1719 UDP 1720 UDP 5060 TCP 5060 ICMP (said they've opened this up for the device, not sure what ICMP means) TCP 1720 TCP 5005 Could it be causing issues...
  8. Ruuvan

    IP9608 - Connection Issues

    Hi, tlpeter, thanks for your response. Yes, all remote worker/extn enabled on the port VoIP settings and against the user and extension. Their IT company are making another change so I'll be testing it again today. Appreciate all the input thus far.
  9. Ruuvan

    IP9608 - Connection Issues

    Thank you, gwebster. Managed to get the Firmware up to 6.3116 but can't seem to get it any higher; have the latest FW (6.4-odd) on the Manager PC with the system pointing to this for upgrades. Is there anything else you could suggest?
  10. Ruuvan

    IP9608 - Connection Issues

    Hello tek-tips, I am hoping you can help me. I have tried to get this working myself from the past threads on here but I'm having no joy, hopefully it's something easy you'll see immediately. 9608 handset configured with WAN IP of main system site, ports forwarded on Cisco router (unsure of...
  11. Ruuvan

    9608 Remote Phone 8.0.56 IPOV2

    When I last had this issue it was the phone not upgraded properly. I had to get the remote phone put back in to the main office (as something was going squiffy pulling updates over the net) and configured for local use on the system; it upgraded and we could log it in/use it fine, continued to...
  12. Ruuvan

    Best VPN Solution for 9608

    Gunnar; it' what has been required of me, so just relaying from my experience. Can't be sure if it's users moving to offices all over the country or what, but that's how I've needed it setup to work -shrug-
  13. Ruuvan

    Overflow calls not working on SCN

    Sorry, to specify; the above Group layouts go in the Overflow > Overflow Group List of the huntgroup that the call first goes to.
  14. Ruuvan

    Overflow calls not working on SCN

    For multiple group overflows you put it all on the first group Group A - Overflow - 15 seconds Group B Group C This will overflow from A to B after 15 seconds, then to C after a further 15 seconds. For more "complex" setups you could do; Group B Group B Group C Group D If you wanted it to...
  15. Ruuvan

    Best VPN Solution for 9608

    Cisco, Draytek, Technicolour; these are some of the models we have 96-series phones working through. All we've ever had to configure on the handset HTTP / HTTPS / CallServ / FileServ with the WAN IP of the main site. As long as all the relevant ports are forwarded on the routers it should be fine.
  16. Ruuvan

    Password stopped working

    Worth adding we tried pretty much everything else we could think of before making this change. You may get some rejections when trying to get in to the security settings to change this initially, but you WILL get in eventually. Same with saving; might take several attempts, but it will. Once...
  17. Ruuvan

    Password stopped working

    One I can help with! Since V9 I have had this issue across many many CCUs. There's no reason for it. The ONLY fix I found was in Security Settings > Services In here, both Configuration and Security Administrator are set to Secure, Low Changing this to Unsecure only has fixed all of my...