Hi guys
I’m installing a Midsize Enterprise 6.2 for the first time on a DL360 G7. The system platform is pre-installed. My problem now is, that I can’t change the default ip addresses and host names under Server Management -> Network Configuration. When I save and wait 7 minutes, it is still the...
Hi Stanley
It's the cheapest way to work with MOBX. It works now with EOD, BUT it's slow.I'm not impressed at all. Actually the Android app. it much easier to work with.
It works, and that's it..
dkl
Thanks Stanley
When I first read your reply, my first thought was No.
I have read this Feature guide rls. 7,5, so may times now, to see if I was missing something. But there was nothing in it, about this EOD
BUT today, when I wrote this question to Tek-tips, I saw that GHTROUT has released a...
Hi
I have a CS1000m SG rls. 7.5
Has anybody worked with the Avaya one-X Lite application for Iphone?
The problem is, that when I press the Enable button, for Simultaneous Ring, it calls the MSA number, and dials the PCAA code, but it only works, if I manually press the # via the dialpad on...
OK have tested it.
Made a rule 1 to RMD "CF2". Did a change and an EDD. Made a RSR 1, and a sysload, and it took the backup from the CF2, and the change is gone.
So conclusion is that we can use the bkdata file, in the same way as the single backup file, while we reinstall software.
Hope this...
Hi again
Have just found that the backup type also is bkdata.1 if you make a rule, which makes a backup to the RMD /CF2 card.
So this means that you can copy the bkdata.1 file to the CF2 card, and install it right away with the software, instead of default database and host etc.
This is much...
Hi all. Thanks for your answers.
bhassell2000: This is of course an alternative, but I wanted to use bkdata file, not the single backup
firebirdscrambler: Good guide, but it also refers to the single backup file
guycable2: This was a hint in the right direction. But when I used RES it started...
Hi bhassell2000
We do also have a backup on the CF2 card, but in case of water etc. in the switch room, we have to be able to do a restore. Normally I would also use the single backup on the CF2.
Or do you mean that you copy the bkdata file to the cf2 card in this case?
Does anybody know how to restore the CS data, which is stored on a FTP server?
The file type is bkdata.1, but I can't see anywhere how to use/restore this file. There is an old thread about exactly this, but there is no answer in the thread.
Hi Latvia1
We have had exactly the same problem. Avaya worked on it, and the solution is a new FPGA loadware AA19 for the XPEC cards. Avaya can look in this case 101031-25132 in the old Nortel cases.
So ask Avaya for this loadware, and it works
/DKL22
Hi ASpark
We have a customer with this problem, same release. In our case it's related to CDR/CTY on the MGC card.
Avaya has been working for this problem a lot, but has not been able to fix it yet. I have just asked Avaya about this bulletin, and asked for the patch for rls. 5.50.
Hi again. Found it. CFWT. If you dont want the tone at all, set it to
CFWT
XTON 000
XCAD 000.
Then disable and enable all conference loops in ld 34, with these commands DISM 0 0, ENLM 0 0. It has to be done for all IPMG's
/DKL22
Hi all
I have a CS1K rls. 6. I cant remeber how to change the conference beep. Does anyone know which prompt in LD56 I have to change this tone.
/DKL22
Hi MagnaRGP
Are you sure, that the database will be migrated.
We are right now installing a new CPPM with HA, instead of our customer's old M81C. I have tried to convert the old database to the CPPM. It is possible, but all 13 PRI now reside in the same loop 252 1 0, and all the D channels...
It is your mgcdb.xml in the pdt, that is wrong. Rename the mgcdb.xml to ex. oldmgcdb.xml, and then change the mgc via mgcsetup. Dont you have a sig server, this is the one who makes these files?