  1. Wcmyers74

    SRPT4653 Errors...

    I found that patch and it is installed and in service. I am not having any QOS issues. Any other ideas?
  2. Wcmyers74

    SRPT4653 Errors...

    @Firebird...are you saying the patch is the fix or the cause of the issue?
  3. Wcmyers74

    Cs1000 release 6 Analogue trunk disconnection

    I have the same issue. Vendor told me analog trunks are not supported on the CS1000 6.0 and we converted to TMDI PRI. Works fine now.
  4. Wcmyers74

    Nortel ICS

    Sounds like you should call Shaw Communications.
  5. Wcmyers74

    SRPT4653 Errors...

    SRPT4653 VGW channel TN 004-00-00-03 (403) connected to farEnd 10.110.24.210:32276 TN 252-00-00-01 (fc01) was closed incorrectly, current state = RxTxOpen Anyone know why this keeps happening on different VGW's? It even happens withing the same MG1010 chassis. I have a 6.0 CS1000 with (6)...
  6. Wcmyers74

    OTM window size in 3.0

    Ok, we finally figured this out. How strange! we had to change the screen vewing size on the server video settings. We had to go directly to the server, it doesn't work if you do remotely.
  7. Wcmyers74

    COM001 Ethernet driver: unit 0 is being restarted

    On Jamiepockets note, we have 92 sites with 8 port switches (not hubs) that have all of the elan connections going to it and then one uplink to the main 48 port cisco switch. I know for sure that the Cisco is set to 10m but what about the 8 port switches, can I set those? They are Netgear switches.
  8. Wcmyers74

    Sig Server Patches Verification

    We have the same issue. It appears that this happens only when the sig server actually loses power and is not shut down properly. We have 93 signalling servers in our network and it has been consistently power issues and not just reboots.
  9. Wcmyers74

    OTM window size in 3.0

    Well, they wouldn't help us because we are not customers even though we paid for their software, that makes me mad. Anyway, we figured this out. You have to adjust the screen settings on the server itself. I still don't understand that, but we did it and it works. Thanks for the help.
  10. Wcmyers74

    OTM window size in 3.0

    Ok, thank you. I will try them.
  11. Wcmyers74

    OTM window size in 3.0

    We have checked both the browser window, etc. Our vendor doesn't have a clue about it. I have searched Nortel's website and can't find anything. It does the same thing on the server its on and any other machine we use. We were thinking about reloading TM to see if that fixes it.
  12. Wcmyers74

    OTM window size in 3.0

    It has always been there since we upgraded from 2.2
  13. Wcmyers74

    OTM window size in 3.0

    Yes, I understand that, but it will show 50 sets lets say, but you can only see it 2 lines at a time. If you scroll down, you can see the rest, it is just the window size is too small. It has nothing to do with the sync, this is just the viewing window size. Not the type of search or anything.
  14. Wcmyers74

    OTM window size in 3.0

    We upgraded our OTM 2.2 to TM 3.0. The window viewing size is only 2 lines deep on searching telephones meaning you can only see 2 sets at a time. Anyone know how to make it bigger? During a prestentatino of the new release, we saw a slide that showed it much bigger, say 5-6 lines long.
  15. Wcmyers74

    CNF020 and TDS005 errors

    Voice Network REL 4.5 5 CS1000MG's REL 4.5 87 CS1000 Branches REL 4.5 NRS, signalling servers running 4.5W Fiber backbone connecting all sites with Cisco Network About a month ago, we had a major network outage. Soon after that, we started getting intermittent CNF020 errors on our branches and...