Just want to add
When IP Office primary is down, IX workplace registers to secondary. All looks normal but If you initiate call from IX client on traceSBC you can see that IX client is still sending the invite to
Primary IP address. I observe Invite received at SBCE, SBCE does not send anything...
Hi UCMen33260,
I programmed SBCE same way you explained with double IP address on public and private side. All is TLS
fail-over happening in my case as well but once failed over I am experiencing some strange behaviour with IX workplace windows and android.
I can make call or two and than as...
Hi UCMen33260,
I am going through the exact same pain as you did. same topology. IPO R11 FP4 SP2. SBCE 8.1. latest patch applied. Equinox 3.8.
Did you get it working 100% or you still have to do some manual changes on SBC.
In my case IX fails over to secondary, presence is there but my phones...
System is Virtual IP Office server edition. Virtual server was created with OVA files ABE_9_0_400_965_OVF10.
Expansion cabinet is IP500 V2. When powered up this was programmed to be expansion unit.
Since IP Office server edition is latest service pack I am trying to get expansion on the same...
I think you are getting this since One of your BCM is 3.6 or 3.7. As per Nortel matrix BCM3.6 is not compatible with BCM50r6 and BCM450r6. You can still get private networking to work. This alarm will allways be there. One way I know to overcome this is to upgrade your 3.6 or 3.7 to release 4.0
I have a same issue on BCM400. Did you guys had any luck resolving the issue
Reports can not be viewed but they come out to the printer correctly. Below is a error we get
• The report server cannot decrypt the symmetric key used to access sensitive or encrypted data in a report server...
Hi,
I am trying to source server for home lab. Can Dell Power Edge 2600 4 GB, Processor Intel(R)Xeon(TM) CPU 2.40GHz.run HyperV?
Currently running Windows 2008 standard.
I am trying to image HD BCM50 R3 using acronis software.
I was able to image BCM450R5, BCM450R6, BCM50R5, BCM50R6 using the same hardware and software setup. R3 is giving me problems. Did anyone have luck with this?
I have created routing service for VoIp fall back dialing. Service is automatic.
When service is on, multiple sets are showing
" Service ON " at all times.
Any ideas why????
I need some help setting Mailbox Manager on BCM 4.0.
It was working when we had a BCM 3.7 release. Since I upgraded client, it shows network error 1722. This comes after I enter my MBox number and password