I just installed a new Nortel VPN Route 1750, everything is working great except one application on a UNIX server. The server is listening on port 513, I've pulled packets and see traffic back and forth but never get the login and get a socket failure, it looks as the the client is trying to...
I tried G729 with the same results, first call is great, second call bites...didn't go to G723. We are guaranteed 75% of the bandwidth so even at 384k it can't be overloading the circuit. They want centralized VMS so G711 is the only option at this point.
Having voice quality issues between a BCM50 1.0 and a BCM400 4.0. I don't own the network, I'm reliant upon their IT vendor, says he has DSCP set up. All Cisco gear. Dell layer 2 switches. No IP sets just trunks. using G711 on a T1, the first call sounds great, second is really poor voice...
Exactly. I believe NRS was sending it to the original place, an analog station and thinking...uhhhh..no you aren't what you think you are nor do you belong where you think you belong.
BUID and TN are correct, had to do a h.323 test and discovered it was an analog set registered under another site. Since the number was listed in the LUDN on the cs1000 he thot it was free. Mystery solved!! We have 39 SRGs hanging off this CS1000 and can't keep them all straight. Thanks for...
only 99 members in an intercom group. I worked in a public k-12 school and we discussed this very thing. have to keep in mind that in an emergency setting you will have students in areas that are NOT covered by phones. Hallways, cafeterias etc...depending on phones alone really won't give full...
I've got a branch office 5.0 with an 1120 phone that will not redirect. All other phones in the branch redirected without a hitch. We've checked VLANs, routing, programming on both the MO and the BO. All of it is good. When I stat the TN on the BO it shows "idle local registered 12" not...
the printcaller piece runs in the background all the time, typically you won't see it once it establishes connection with the my_SQL data path for RCC. If you are still seeing it, click the details button to see the errors. Also make sure the machine is not going into power save mode...
Is this a client tunnel to the BCM or a Branch Office type tunnel with the serts at the branch office? You might want to find out what the lease is on the IP address assigned by the ISP if it is a dynamic address. If the address is dynamic and is getting changed, then the tunnel would have to...