Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. exmcier

    GUI on on conference bridge cards locks up

    It used to happen infrequently, now it is happening every other day os so. The Web GUI on the conf bridge appears to lock up on any/all of our Nortel ICBs. Whn I lock up occurs we stat the card (see below), disable it, reseat it, then re-enable it. Then we are back in business until the next...
  2. exmcier

    IP Phone Server Error

    This looks very helpful, many thanks.
  3. exmcier

    IP Phone Server Error

    They are HP DL320s. We couldn't open them up because we couldn't take them out of service at the time but we assumed that these particular ones had 2 gig of RAM. HP Specs stated that they could go up to 8gb but vendor said 7.6 had an issue with expanding memory on them (assuming those memory...
  4. exmcier

    IP Phone Server Error

    KCFLHRC- you were 100% spot on. Thanks. The PD service had to be started on Sig Server 2, and that did the trick. I raised concerns earlier w/vendor regarding TPS only on one sig server also, but it turns out according to our vendor, our sig servers are so old and constrained by memory that 7.6...
  5. exmcier

    IP Phone Server Error

    Thanks KCFLHRC. Still looking. I know we don't use/support personal directory feataure. what we did do during the install is to make the signaling server that was previously primary now the secondary, and the previously secondary one now the primary, and reconfigure where before one sig server...
  6. exmcier

    IP Phone Server Error

    We just upgraded from 7.5 to 7.6. When selecting the "callers" button on IP Phones, a "server error, try later" message appears on IP Phone display. Has anyone else encountered this? Any ideas are greatly appreciated. Thanks.
  7. exmcier

    Calling Party Name Delivery - CS1000

    What I figured. At the mercy of Telco to re-register a single DID. Re-mapping caller ID/ANI works. Re-mapping Calling party name does not. Probably has to do with which NI2 parameter Nortel wants to use versus what parm NI2 requires for transport of calling party name?
  8. exmcier

    Calling Party Name Delivery - CS1000

    I'm trying to find out if there is a way to send out an overide calling party name over an NI2 PRI. I've played with. I've added a CPND name to the CLID table via UCM web GUI, but no luck. CNDA is set to Allowed. Any ideas?
  9. exmcier

    RLI Limit

    Thanks Firebirdscrambler
  10. exmcier

    RLI Limit

    We've got 47 RLI defined on our system. When I tried to add a new RLI (RLI 48) I get an error. I know BARS allows for up to 128 (0-127) RLIs. Does anyone know if there is a local limit defined somewhere and if so how can I change this so I can add a couple of more RLIs?. This is a great forum...
  11. exmcier

    CS1000 and Nortel Integrated Conference Bridge

    7.5 went in without patch MPLR 32292 and MICB conferencing problems encountered on this try.
  12. exmcier

    CS1000 and Nortel Integrated Conference Bridge

    Just an fyi. On March 19th Avaya released a PCN against 7.5 stating the removal of patch MPLR32292 from all deplists as it caused MICB problems as well as CLID display problems. Will see......
  13. exmcier

    CS1000 and Nortel Integrated Conference Bridge

    Hmmm.... loadware was verified by Vendor remote technician. When the board was STAT'd the ports were showed up as logged out. Rolled back to 6.0 and now all three boards work. Will have to see what Avaya says.
  14. exmcier

    CS1000 and Nortel Integrated Conference Bridge

    Last night we went from Rls 6.o to 7.5. After we did the Nortel Conferencing stopped working. All three conferencing cards stopped working with 7.5. Put one side back to 6.0 and two of the conferencing cards started to work again. Don't want to fall back to 6.0 as we would have to rebuild all...
  15. exmcier

    CS1k NXX Table

    Thanks for confirming KCFLHRC. So if I want to make "511" an SPN (511 by itself, no other digits dialed i.e., no 511+xxxx) then I need to delete 511 as an NXX, set it up as an SPN, assign an RLI number and make sure to strip one leading digit (AC1) off of it (DMI) before sending 511? Caller...
  16. exmcier

    CS1k NXX Table

    In looking at out CS1k NXX table ( Re: LD 90 below) REQ PRT CUST 0 FEAT NET TRAN AC1 TYPE NXX NXX 360 NXX 360 RLI 1 SDRR NONE ITEI NONE UDATA: 202376 8 PDATA: 219595 518 DISK RECS AVAIL: 512 Since it doesn't ask for an NPA, I am assuming that there is only one NXX table on a CS1k and that...
  17. exmcier

    CS1K - Max Concurrent Calls in Progress

    GHTrout, I can kind of get max number of calls on each trunk via CDR reporting utility, but the time frames for each trunk vary somewhat. I was hoping to get max concurrent calls in the switch (say for a given 24 hr period). It looks like I might not have any options. As always, thanks for...
  18. exmcier

    CS1K - Max Concurrent Calls in Progress

    Triton101 & John Poole, thanks for the quick feedback. I guess I know what I'm doing tonight....Reading the Nortel Doc that Triton sent. Thanks Guys
  19. exmcier

    CS1K - Max Concurrent Calls in Progress

    Does anyone know if there is a way to find out the maximum concurrent calls in progress for a given period of time without having to sift through CDR data via Infortel utility?

Part and Inventory Search

Back
Top