If you reboot it then its possible that this happens , look at the prompt for callforward on sysload,or if you built the group and didn't data dump the switch.
[2thumbsup]
Hans
KPN Holland
When you make a conference same happens. But there was a college for me on the customer location and he solved the problem with a new deplist. thanks everybody.%-)
Hans
KPN Holland
Hello
when i place a call from cs1000 over sip route to a cs 1000m and i want to transfer the call to an outgoing trunk, then after the connect the vgw disconnects. does anyone know whats the problem here.cs 1000 rls 5.5 cppm
Hans
KPN Holland
Hello all
it seems like the troubles are over now.
I changed the cabling in the right direction and the problems are gone.
thank you everyone[2thumbsup]
Hans
KPN Holland
Hi
In OTM Station Admin select the TN.
Then, in menu, click Edit,Edit Specification (DROPDOWNMENU) select: SYNCSTATUS.
Then in Old Value select TRN.
In New Value select NEW.
The click ADD and after this submit
[2thumbsup]
Hans
KPN Holland
Thank you GHTROUT [smile]
I did not read the message wel.
I had the problem at a customersite, and saw that on 2 locations the connection was wrong.
this afternoon I switch the cables and look or the problems are gone.When te change is succesfull I Reply again on this Post.
The answer is ...
Hello everyone
[I have a question about meridian max]
the problem is when i login as a supervisor in MTe or a console,i logout automatic after 2 minutes
does anyone know something about this problem???
Or are there timers to set, So you logout after a specified time???
[Thanks everyone]
Hans...
Hi Atilv
go to ld 2
then do
stad
first set date 07 04 2003
then set time 14 00 01
then do a cr(carriage return)
To display if the time is right
do ld 2
ttad
then you see the time and date[pc3]
succes
Hans KPN Netherlands Hans
KPN Holland
He Howi
Try to change the compression on one of the phones that you are using in 711 codec and then try to call whit that phone
maybe is the problem bandwidt or a firewall what makes the troubles in the rob box
Greetz Hans KPN Netherlands
What you also can do is make a idc tabel in ld 49
that is very simple to do
idc is incoming digitconversion
look to your ntp for more information.
greetz from Hans Tuinman
(KPN telecom Netherlands)
i dont know or it works whit otm
but when you have a terminal program like procomm
you can find that info in ld 81
ld 81
lst
than you do a carriage return til the prompt feat
there you fill in what youre looking for:for example
when you fill in dsp en then you do a carriage return
twice...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.