If it's the same issue restarting service after system restart would be enough.
If not well a lot of possibilities
You can try
- check connection between SCCS and MMail (access link)
- check this link using MMail tools level access
- check your COM2 settings and it's status
Hi
1) To enable/disable NCOS:
LD 15
REQ: CHG /PRT
TYPE: FCR_DATA
..
NFCR YES (to enable NCOS or NO to disable)
2)Permissions trees
LD 49
REQ NEW/CHG/PRT/OUT
TYPE FCR
CRNO x
INIT ALLOW (to ALLOW everything or DENY to deny everythinh except:)
DENY (to deny some ranges if previouse ALLOW)...
Hello
Could anybody tell what is the difference between types "L500" and "500"?!?
And where should I look for the reason of PBX reaction:
- when I'm setting new phone of type "500" - PBX is switching it aoutomaticaly into profile "L500"! ???
Thanks a lot
I figured out that I can't use PTY for simulation of printer for ACD, because this is not permittet (USR ACD).
I've created regular one...
Thnaks a lot for helping
Hi
Just simple repost of question :
Could you please provide me walkthrough how to program 'virtual' (not existing) printer? And how to assign PRIO number to it?
I don't have any
When I'm trying to create new one I have parameter PRIO which is printer id as I read in man. I don't have any programmed in system
How to do it?
Hi
I'm trying to perform some ACD configuration on Opt 81.
To accomplish I'm missing HOML parameter-it's never display. I've found in docs that HOML is present only when SDB is defined but to be true I don't get it.
Please help me with resolving this issue.
Hi
I have problem with SCCS 4.2 instalation. After reboot system comes up but MM Access link is down. This is caused by problem during startup service MAS LinkHandler#2. It fails to start automaticaly on startup.
After few minutes I'm able to bring it up manualy and everything is working fine up...
Hi
I'm setting up some hunt group on Meridian Opt 61c
I wish this list to be managed by user so I put on one of the phonesets
zz KEY SCC xxx wher xxx is my ght list configured in ld 18
Everything is working fine - user can add or change entries unless there is a need to REMOVE one entry from...
Hello
I have Sympsoium Server 4.2 and Opt 61c
there is one CDN number acquired by SCCS.
SCCS works ( agent's are logging with their ID ) but all calls are routed to default ACD.
After such situation i got on switch errors like :
BUG 194 (Attempt to remove CR from CDR queue while queue is...