Hi
it depends on the system, which you use as an external system and what the external system support as a protocol..
Generally for IVR or call detection systems , DPNSS or CAS is used... (TLU76/2 or 76/3)
But also it's possible to use qsig or euro-isdn with external systems
But if you use...
We have CCM server 4.0 SP3 on MD110 BC10 version
We have been monitoring approximately 450 agents and 50 ACD groups with this system..
But after couple of days we will need no longer to monitor these amount of agents and ACD groups because of Genesys Contact center implementation. I mean CSTA...
Hi syncfail,
Genesys T server has a network tcp connection with Application Link, and of course application Link is connected to md110... Genesys 6.5 sends requests to Application Link , and Application Link sends it to Md110 via CTI links
Which connection parameters do you want to see...
Hi all,
Problem was fixed by Ericsson Local partner, by replacing LPU5 card on LIM9..
He told that no problem seemed on LED or any on that LPU.. But it's the reason for the problem.
Rgrds
Think that,
5340 is a digital extension located in 3-1-40-02
5440 is a digital extension located in 4-0-40-02
5652 is an ACD group configured in LIM 6
There are TMU cards on ,
lim6 magazin 0
lim6 magazin 1
lim4 magazin 1
lim3 magazin 1
lim8 magazin 0
Question1 When the ext.5340 calls the ACD...
Hi ,We use Genesys 6.5.304 T server with MD110 BC10 Application Link 4.0 SP9 HF03
On NCSTA tool of Application Link, I could send DTMF tone after i dialled a number, (We do not use "9" digit before sending dtmf)
But when i tried it from Genesys Side, it gave "invalid call identifier error 1150...
Hi,
This is the result for fiscp
<FISCP:IODEV=SYSDISK1;
FILE SYSTEM CAPACITY DATA
TOTAL DISK SPACE: 122 MBYTES
SUBFS: SYSSUBFS11
KBYTES FILES
TOTAL AVAIL TOTAL MOUNTED
40960 39728 10000 /SYSN/USR1
SUBFS: SYSSUBFS21
KBYTES FILES
TOTAL AVAIL TOTAL...
...16:02:34
CLASS: 4
102 POWER FAILURE DETECTED BY DSU
DATE TIME ALP NOIF EQU INF1 INF2
27OCT04 15:55:43 1 1 007-0-**-** 2 4
CLASS: 3
85 BUFFER TRANSFER HAS FAILED
DATE TIME ALP NOIF EQU BRDID INF1 INF2 INF3 INF4
27OCT04...
...10:58:50
CLASS: 4
102 POWER FAILURE DETECTED BY DSU
DATE TIME ALP NOIF EQU INF1 INF2
26OCT04 12:20:08 1 1 007-0-**-** 2 4
CLASS: 2
15 DEVICE BOARD FAULTY OR MISSING
DATE TIME ALP NOIF EQU BRDID
26OCT04 12:21:29 2 1...
Hi all,
The problem is still same.. No change.Our vendor also had done the procedure before, about what antek said.
By the way, removing these program units, cause other program units fail during DUSYI process..My other topic was also related with this issue , "dusyi fails because of DMGM PU"...
Hi
The system is BC12SP5 and 9 lims..
The problem occured after adding new lims..(2 lims were added)
<dubdp;
BACKUP DATA
EXTERNAL BACKUP LATEST PREVIOUS
REL1 REL2...
...9 3
85 BUFFER TRANSFER HAS FAILED
DATE TIME ALP NOIF EQU INF1 INF2 INF3 INF4
20OCT04 14:10:42 2 1 006-0-**-** 315 6 6 7
LAST ALREI: 20OCT04, 14:08:38
END
<DUSYI;
SYSTEM DUMP INFORMATION
NO VALID RELOAD DIRECTORY EXISTS
RESULT OF...
Hi ,system is BC12 SP5,
Does anybody have any idea what to do it so? (It had given an error on AOM8 PROGRAM UNIT.And i had restarted drdh program unit in lim1 and it had dumped succesfully.) But now restarting drdh is not a solution..
<DUSYI;
SYSTEM DUMP INFORMATION
NO VALID RELOAD DIRECTORY...
Hi jerromeke,
I think you're right, it's about network issue. I saw that our Tserver has 10Mbit half-duplex ethernet port
And also Application link had 10 Mbit half-duplex.
And we saw lots of data collisions.
Firstly, we changed Application Link ethernet port 10 Mbit full-duplex
and this week...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.