We've seen environmental sensors attached to gateways in the past, as well as the ups being connected to the gateway using either lan port 1 or 2, and thereby relaying information across the network so that it can be monitored remotely. How is this configured in the gateway? We're rolling out a...
In thread thread690-1745537, it was asked how to load the shellshock remediation onto CM 5.2.1. One answer said that you can use the web interface, the next response said to use the linux command line. Which way can you do it? Can you go either way? Just needed some clarification.
Thanks.
Is there a way to push patches out automatically? We've got over 100 sites with LSP's and media gateways and a duplicated core switch. We're doing System Platform patches and CM patches now, but are doing them one by one, which takes a LOT of time. Is there a way to automate this?
We got a site with an S8300/G450 with a 6 member trunk group of CENTREX lines. We had an issue not long ago with dropped calls. LEC says they found no issue, they left and it started working fine, go figure. Now, we are getting echo intermittently on a few calls every now and then. Any ideas? We...
Have you done a 'nvram init' on the G450 before doing anything else? This will clean out it's RAM and memory, then restart programming. Upgrade the firmware on the G450 to latest, and make sure you load it on both Bank A and B, then login and see if the MM711 can be seen then.
Sounds like a network issue between India and Hong Kong. Something is dropping the link. The ip phones should be loaded with the ip address of the call server, the vlan id, and the gateway. If they connect, and then later disconnect and go into discover mode, that tells me that the network...
Dumb question, but are you logging into the correct switch? If this is a large corporate environment with many sites/switches, make sure you're attempting to log into the correct one with your web browser. Also, make sure you can ping the switch, and that your browser isn't just loading a page...
What he said. On the first two, it's a pair on the AUX field, which is connected to the board. On the Prologic, it's a serial modem connected to the octopus cable on the back of the processor.
I did an install last week for a business partner. The IP Office was loaded with 8.1.63, and we were told that 8.1.63 was acting 'buggy'. They didn't go into specifics, they just said they had just found out that 8.1.63 was 'buggy' by someone at tier 3/4 Avaya, for what it's worth.
Okay, we discovered a 'gotcha'. VAL boards firmware MUST be upgraded to at least ver. 21 PRIOR to going to version 5.2.1, not AFTER. Lesson learned. It they're not updated before, they may get stuck in a 'reboot' cycle. We had two VAL boards, one came up, rebooted a couple of times (went through...
We're about to upgrade a duplicated S8730 server from 5.0 to 5.2.1. I've got the latest service pack and firmware updates, and have made sure that the ip phones do not get their firmware from the S8730's. Are there any other gotcha's I'm overlooking? Seems straightforward from here. I saw a...
thread690-1644618
Did anyone find an answer for this one? I'm in the same boat. I've figured out duplication link and services port, but I need to know where to plug Control Network A, B, and corporate LAN.
Thanks,
Barry
We're about to upgrade our old CM 3.0 to 5.2.1. I'm looking at our hardware and I'm trying to determine if we have Control Network A and Control Network B or is the IPSI's merely duplicated. Is there an absolute way to tell??