We have managed to connect 2 md 110 with Cisco and E1 interface with q sig.
Everything works fine.
Has anyopne managed to have q-sig functionality with 2b+d interface?
Well we have a bc 9 system with 60 ctt10 positions and every time this happens we have to call CEMEA.
They log on and fix problem. I think problem is with some hunging records.
Hi we have same cases Ivr connected with tlu76/3 and we experienced many problems. We played around with the icat parameter of the cas extension and now no problem.Still since it works internally I would say that changing the type of number in the nutri might help.Also check that there is no...
In bc9 it works for some trunk units eg tlp11 but not for slp60 (isdn).For that there are about 20 patches that allow pt in isdn signalling I tried it and it works .For bc 11 it works fine and no patches are needed.All above are for st application
TRY TO SET THE MINIMUM CATEGORY TO THE DESIRED ONE IE EXCCS:CATTYP=1,CAT=CATEGORY FOR DISA WITHOUT AUTH CODE.
BE CAREFUL . DO NOT LEAVE HOLES ON YOUR SYSTEM.
USE PARAMETER CUSTOMER FOR THOSE EXTENSIONS.
IN THE LCDDI:TAB=FDT,FRCT=X,PRE=A;
IN THE RODDI GIVE RODDI:DEST=A,ROU=...;
GIVE ANOTHER RODDI WITH CUSTOMER.