Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations TouchToneTommy on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. sostek

    Wirless connectivity problems

    Actually I should have mentioned, this PC did at one time work with the router in question. So I'm not sure it's the card. I did ask the client to check the version of the card since the 2200's had several revisions.
  2. sostek

    Wirless connectivity problems

    Here's one I've been working on for a client. They've got three pc's, PC one is a desktop running Windows XP Home edition with a Netgear wireless card. PC two is an Apple MacBook PC three is a Dell Inspiron 600M laptop with Intel 2200 card. They have Cox for their broadband provider and...
  3. sostek

    MWI light not illuminating

    werdcrime: Thank you. I think that fixed it.
  4. sostek

    Having audix announce name/extension

    Is there a way to get Intuity Audix LX 1.1 to announce the party name and/or extension when transferring a call received by an auto-attendant?
  5. sostek

    avaya -vs- cisco

    I wouldn't touch Cisco's solution. It depends upon, you guessed it, MS Exchange. Anything that uses a sub-par Microsoft product to by the linchpin of their flagship is definitely trouble. I'm fighting that battle in my office now. They don't like the Avaya system mostly because they don't like...
  6. sostek

    MWI light not illuminating

    Kevin, On page 2 it's set to MSA-SPE which works on other stations (7406D's and 8410D's) without issue. Audible was set but it wasn't even getting that.
  7. sostek

    MWI light not illuminating

    I have two systems, the main one to which the Audix LX is attached is a Prologix G3iv11. The remote system is a System 75 Definity G3iv6. I have one extension on the System 75 where the message waiting light will never light. I've swapped out the phone (7406D), and the port to no avail. I've...
  8. sostek

    Intuity Audix Auto Attendant

    Is there any way to get Audix to announce the persons name before it transfers a call to their extension?
  9. sostek

    Survey - Do you self maintain your Avaya system?

    Back in 2001 I was working for an agency that had a G3iV6 System 75. At the time we were paying outrageous fees for hardware support. As luck would have it, we found out that another agency was getting rid of their Definity system. The cards between systems are pretty much the same, with the...
  10. sostek

    Backups....

    We've run into that problem already. We've got about 200GB of data to backup regularly and most tape drives that we have are 20/40GB. We also found tape to be somewhat unreliable. So we bought an HP Proliant ML150 G3 with 2TB of space on it. Used Debian and rsnapshot as well as the lvm to join...
  11. sostek

    Problems transferring calls

    I figured it out. In the trunk definition for Archives on Switch A, I had to set disconnect supervision for inward calls. The thing that tipped it I realized I was doing a trunk to trunk transfer (Normal to DCS) and if supervision wasn't passed along, it'd disconnect within six seconds.
  12. sostek

    Problems transferring calls

    Ok - I have two Definity switches connected via DCS over a PRI circuit. Person dials our Archives division. Their service is attached to Switch A via an MCK over PRI. They try to transfer a call to Switch B (DCS) and the call goes but after a few seconds it drops. Interestingly if the person...
  13. sostek

    G4 Powerbook OS-X 10.2.8 won't connect to WAP54G

    I have a Linksys WAP54G with WPA TKIP personal turned on. I've recently received a G4 Powerbook and am trying to get it to connect with no success. It connects to a Linksys 802.11b device in my office, but not to my WPA protected G router. It's OS-X 10.2.8 and I cannot believe it can't...
  14. sostek

    Problem adding a 6408D+

    Found the problem. This is what happens when you have others do the job for you. The designator strip on the port side was partitioned into eight sections, so when I told them 01A1004 they in reality put the station on 01A1016. So the phone was just sitting on a TTI port and I didn't know it...
  15. sostek

    Problem adding a 6408D+

    We have a G3iV6 system that has one 6408D+ already on the system connected to a TN2224 card. The existing extension is dialable from both the G3iV6 and the prologix since the UDP settings are good. When I setup another 6408D+ on the same TN2224 card and try to call it I get a busy signal. If I...
  16. sostek

    Problems with web access to Avaya Intuity™ AUDIX® LX R1.1

    That would be all fine and dandy but when you login as sa you're immediately launched into X-Windows and the ssh session to the box comes up. We need to modify the certificate.
  17. sostek

    Problems with web access to Avaya Intuity™ AUDIX® LX R1.1

    When we moved our office we also moved our Audix system and put it on a different IP network. I can access the admin pages but when I try to do messaging administration it craps out. It's definitely related to the certificate that Avaya uses. How do I change the cert information so that I can...
  18. sostek

    Why does VB add a # on the end?

    Might that be an overflow indicator?
  19. sostek

    Extend LAN using Wireless

    You can probably get away with this, but I think you want to use a wireless router as opposed to a wireless access point since the router will do DHCP, the WAP won't. If you already have a DHCP server in place, the WAP can do DHCP pass through.
  20. sostek

    Speak English....

    Here's what amazes me. Everyone is saying how business saves a bizillion dollars outsourcing tech support to India, but in reality where are those savings being applied. Prices are pretty flat on most IT gear, so the money has to be going somewhere.

Part and Inventory Search

Back