SSCs are a fussy bunch. Shut off the PBX, pull out the SSC, reseat the SSC, and turn the PBX back on. If that doesn't fix it and you swap SSCs don't forget to move the security "Coin" in the upper corner over to the new card.
Use the XMWK key instead of MWK. You can specify what extension you want that message key to represent. MWK only indicate Primary DNs or a signle appearance non-PDN. XMWK MUST be a non-PDN.
NTDK22 is a single port duaghterboard!
You need a NTDK84 Dual port daughterboard in one of the SSC duaghterboard positions if you want 3 expansion cabinets.
Can you post you ADAN for the DCH, RDB and TNB of a trunk?
Is there only one PRI or multiple? if mulitple are ther muliptle DCH? If so, are they Primary/Backup or individual configuration?
Hi all,
I work on a HMS400 and they have had NPR500 BAD LAMP errors for all of the 2nd lines of the analog room phones printing on their BGD printer since install. There are 2 extensions in each guest room (Line 1 and line 2 of a single 2 line phone) and each line is associated with the single...
I would like to power off the mermail module but don't want to throw a column light. We put in a server based mail. Mermail is the bottom module in a column so it will just sit there until I can convert it to an IPE module. Is there a way to turn the module OFF without throwing the column light?
So I hear that you should always bring Ground start trunks into the PBX rather than Loop start as Loop start will have disconnect supervision problems. Anyone else heard this and have any insight. I have never had issues with Loop start trunks on any Nortel PBX I have worked on. Maybe I'm lucky.
I have recently been inundated with 2216 and 2616 sets where the digit 8 and some with the digit 0 just quit working. It is definitely the set as when a new one in put in it works fine. Is there and documentation showing that these sets have a tendency to go bad in that area of the dial pad? Has...
On the phones where you have multiple lines, try making all lines busy then place an additional call and see if it goes to voicemail correctly. In the Octel there is a feature in some mailboxes asking to check for matching mailboxes. Make sure that the check for matching mailbox is set to "no"...
I have used the MCK 7000 and it is a good product. It interfaces with the meridian 1 via digital tn's with no need for the reach line card. That means the TN's will be located at your host site not at the remote site. It will allow for 24 digital phones and can be coupled with the MCK 6000 which...