I thought it may be the nework problem at the very begining. After isloate from their network. Problem still there.
Any tips to me for how to run the RDM.exe?
Hi,
DNA 5.5 sp3 with hotfix 301 and 304. OS is W2003 server SP2, SQL 2005 express onnecting 4 OWS with XP.
When F9 key 9 detail or F11 message key is pressed, it hangup for 15 seconds to 30 seconds sometimg. The worst is nned to restart the RDS in server.
Anyone meet this problem?
Hi Parnum,
Thanks for feedback. My old way to install CCM is like this.
Install DNA, use SQL 2000 MSDE. Remove DNA, then the SQL 2000 MSDE retain. Then install CCM server.
From W2003 sever SP1 or above, you need the CD key when you chose SQL 2000 MSDE during the DNA setup.
But if the OS...
Hi,
Does somebody try this - use SQL 2005 express in CCM 4.0.
One customer CCM PC crashed, it is running W2k, MSDE. Now we want to change a new PC With W2003 server.
I have experience when I install the MSDE in W2003 server SP1, I need to input the CD key but what is it?
No propblem install...
Hi,
I get a problem. The connector symbol in the statusbar of OWS is not connected, hence name seraching failure.
The below are IP setting:-
1. OWS IP, Mask and Gate. 192.1.52.101 255.255.255.0 192.1.52.251
2. DNA IP, Mask and Gate. 192.1.40.167 255.255.255.0 192.1.40.21
3. PABX...
Hi Lee,
I am afraid this is not true. all all clients using MX-1 4.1 UM connecting to TSW and BC12,the MWI without problem. I have opened a ticket regarding this latest version 4.2.
Hi,
Our demo system with this problem. The mailbox with UM, the MWI not work. Message OK on both DTS and outlook. While mailbox without UM, the MWI OK.
I try to install another new PC with MX-1 4.1, no such problem happen. I think this relate the MWI component in the Exchange Server, this...
Yes, they told me so. I haven't do anything yesterday and they change this setting. they have relevant information from Australia. After that, all basic call are OK.
May be still got something they haven't told me!
I will try the RODAP and ROCAP today.
Thanks.
Hi Mundus,
problem fixed by Nortel people. They change protocol from ISO QSIG to ITU/ETSI.
Anothe problem. Nortel call MD110, name display OK, MD110 call Nortel not work. I have started the STI and find that no name appear in the signal trace.
Any parameter I need to change?
Hi Mundus,
After change the bit, result is the same. here is he feedback from Nortel Regional support.
"From the observation, I have some findings from the captured E1 PRI QSIG D-channel monitoring message logs.
Based on the D-channel message at test result from Nortel --> Ericsson, if...
Hi Mundus,
Thanks. I will try this tomorrow and will discuss with Nortel. But I am worry is no networks facilities!
I am thinking, VARI D1 is set to 3, which is ITU-T/ETSI, nortel tell me they don't understanding this, they only know ISO QSIG, will this be the cause? I have tried around D1...
Hi Mundus,
I am appreciate for your feedback. The STI has done but I don't know the contents as I am not the expert in this area. By the way, can you have a look in this trace so that I can discuss with Nortel staff in this problem?
<STRAP:TRI=1;
TRACE IND READ RESULT
TRACE INDIVIDUAL NO 1...
Hi,
Any one have route parameter for Nortel M1?
Call from Nortel is OK but call from MD110 is always failure. Notel tell me this is our fault because call from them get no problem. This is non-sense.
There is product bulletin regarding QSIG between M1 and BC11. Anybody can have this paper...