The only thing I've noticed is that if an extension is deleted, then the destination is blank for the DID it had. The DID still exists, there's just no destination for it.
If the entry is completely gone I would check the audit trail log for any hints.
Pretty sure all SIP FW is the same for 6900 Phones.
You could try the below, will be version 6.4.0.2009
https://fwdl-mivo400.mitel.com/6700i/7-1_SP2_HF1/6920.st
What type of MiVoice?
- MiVoice Office 400
- MiVoice Business
It's confusing but there are 53xx series phones on both systems but they are completely different.
6800 series phones will not be MINET FW so limited features as they will be SIP only on a MiVB.
If you login as 1st-tenant-admin and check System Configuration, Recording Planner > Compliance.
There could be a few rules in there regarding what to record and what not too. There is a Call Duration option so I would look there first.
The install document has the "Preparing the server before installation" section.
https://www.mitel.com/document-center/applications/contact-center/micontact-center-business/micontact-center-business-for-mivb/101/en/micontact-center-business-installation-and-administration-guide-for-mivb-platform...
You can change the CallerID displayed on inbound calls using "Inward Dialing Modification", then apply that to the SIP Trunk (Assuming SIP)
We use this to display the correct number coming in so that we can call back a missed call.
e.g. in Australia (Telstra) a call usually come in with 9...
The problem is that if you try and use an i-button that is in use on a customers system that you don't manage, you can't clear it.
e.g. If you buy a system from eBay, you won't be able to use the i-button because it will be locked to an existing ARID.
As an FYI I have tried one of these that were linked from jrpuder a few years ago. It registered on the AMC fine and licensed the system.
As it was new there was no risk of the ID being used by a previous system. I did not put it in to production but it appeared to work fine.
@Billz66
Yes it's...
Correct, it is a timer for Unsupervised CO (Limits the duration of outside calls transferred or forwarded to outside numbers before recalling the primary attendant.)
System > Timers and Limits > Unsupervised CO (Value from 1 - 255 minutes)
We do something similar to Billz66.
- Backup existing system
- Restore into lab environment
- Change IP addresses in lab to suit new environment
- Backup lab systems
- Restore into new environment
It's a little more stuffing around but works well for us.