i have an openscape desk pjone cp200 ( HFA soft) stuck on screen "UNIFY" and not booting . is there any solution like DERT for openstage phone.
besty regards
HELLO .
I have problem with the power box for hipath 4000 as shown in image , i'm wondering is it possible to buy a new UACD power box (Lineage Power) ? from Where? Any help to repair it or replace it. the rectifiers are working but no battery backup
hello;
could any one give me the required config (command line on comwin) to configure one sip trunk on hipath 4000 V6 , STMI4 ard configured with FCTBK=2 ( BCHL3550=20, BCHLSIP= 20 , BCHL3550=20)
best regard
Taha OKACHA
Hello
I want to interconnect an Aavaya ip office 500 and a hipath 4000 V6 (STMI4) with sip trunk what config i would make on hipath 4000 , any one could explain how to config a sip truk
Best regards
taha
this is a regen of my stmi card
<REGENERATE-CGWB:LTU=4;
REGENERATE-CGWB:LTU=4;
H500: AMO...
hello;
i think that you should first use
CHANGE-TAPRO:STNO=xxxx,STD=60;
and then conect your module in your display the phone is detected as
| [highlight #CC0000]OPENSTAGE 40 T[/highlight] | 0 | FF FF FF FF | | 0 |
best regards
okacha
HELLO;
THANKS SBCSU I HAD TRIED STNOOS BUT IT DOSN'T WORK ANY OTHER SOLUTION.
THIS IS MY ACSU CONFIG AFTER CHAGING AND TEST:
<DISPLAY-ACSU:ATNDNO=3901;
DISPLAY-ACSU:ATNDNO=3901;
H500: AMO ACSU STARTED
+--------------------------------------------------------------+
|...
please any help how to configure forword for attendent to a digital subscriber (SBCSU) when LAN failur occur for STMI4
[highlight #CC0000]LAN CONN. . . . . . . . . . DEF
LINK SIGNAL ETHERNET . . . . NOT PRESENT[/highlight]
<dis-navar;
DIS-NAVAR;
H500: AMO NAVAR STARTED...
please any help how to configure forword for attendent to a digital subscriber (SBCSU) when LAN failur occur for STMI4
[highlight #CC0000]LAN CONN. . . . . . . . . . DEF
LINK SIGNAL ETHERNET . . . . NOT PRESENT[/highlight]
THIS COMMAND WILL GIVE YOU ALL ASSIGNED NUMBER FOR ANALOGUE
<DISPLAY-SCSU:STNO=2000&&2999,TYPE=CONN,CONN=DIR;
DISPLAY-SCSU:STNO=2000&&2999,TYPE=CONN,CONN=DIR;
H500: AMO SCSU STARTED
-----------------------------------------------------------------------------
DIRECTLY CONNECTED...
Hello every one;
I have a problem when a LAN failure occur on HG3500 (STMI4) Lan
<DISPLAY-SDSU:STATUS=ALL,TYPE=PEN,LEVEL=PER2,LTU=4,SLOT=79;
DISPLAY-SDSU:STATUS=ALL,TYPE=PEN,LEVEL=PER2,LTU=4,SLOT=79;
H500: AMO SDSU STARTED
LTG1 (PERIPHERY)...