i have an openscape desk pjone cp200 ( HFA soft) stuck on screen "UNIFY" and not booting . is there any solution like DERT for openstage phone.
besty regards
HELLO .
I have problem with the power box for hipath 4000 as shown in image , i'm wondering is it possible to buy a new UACD power box (Lineage Power) ? from Where? Any help to repair it or replace it. the rectifiers are working but no battery backup
hello;
could any one give me the required config (command line on comwin) to configure one sip trunk on hipath 4000 V6 , STMI4 ard configured with FCTBK=2 ( BCHL3550=20, BCHLSIP= 20 , BCHL3550=20)
best regard
Taha OKACHA
Hello
I want to interconnect an Aavaya ip office 500 and a hipath 4000 V6 (STMI4) with sip trunk what config i would make on hipath 4000 , any one could explain how to config a sip truk
Best regards
taha
this is a regen of my stmi card
<REGENERATE-CGWB:LTU=4;
REGENERATE-CGWB:LTU=4;
H500: AMO...
hello;
i think that you should first use
CHANGE-TAPRO:STNO=xxxx,STD=60;
and then conect your module in your display the phone is detected as
| [highlight #CC0000]OPENSTAGE 40 T[/highlight] | 0 | FF FF FF FF | | 0 |
best regards
okacha
HELLO;
THANKS SBCSU I HAD TRIED STNOOS BUT IT DOSN'T WORK ANY OTHER SOLUTION.
THIS IS MY ACSU CONFIG AFTER CHAGING AND TEST:
<DISPLAY-ACSU:ATNDNO=3901;
DISPLAY-ACSU:ATNDNO=3901;
H500: AMO ACSU STARTED
+--------------------------------------------------------------+
|...
please any help how to configure forword for attendent to a digital subscriber (SBCSU) when LAN failur occur for STMI4
[highlight #CC0000]LAN CONN. . . . . . . . . . DEF
LINK SIGNAL ETHERNET . . . . NOT PRESENT[/highlight]
<dis-navar;
DIS-NAVAR;
H500: AMO NAVAR STARTED...
please any help how to configure forword for attendent to a digital subscriber (SBCSU) when LAN failur occur for STMI4
[highlight #CC0000]LAN CONN. . . . . . . . . . DEF
LINK SIGNAL ETHERNET . . . . NOT PRESENT[/highlight]
THIS COMMAND WILL GIVE YOU ALL ASSIGNED NUMBER FOR ANALOGUE
<DISPLAY-SCSU:STNO=2000&&2999,TYPE=CONN,CONN=DIR;
DISPLAY-SCSU:STNO=2000&&2999,TYPE=CONN,CONN=DIR;
H500: AMO SCSU STARTED
-----------------------------------------------------------------------------
DIRECTLY CONNECTED...
Hello every one;
I have a problem when a LAN failure occur on HG3500 (STMI4) Lan
<DISPLAY-SDSU:STATUS=ALL,TYPE=PEN,LEVEL=PER2,LTU=4,SLOT=79;
DISPLAY-SDSU:STATUS=ALL,TYPE=PEN,LEVEL=PER2,LTU=4,SLOT=79;
H500: AMO SDSU STARTED
LTG1 (PERIPHERY)...
hello
I had listen to what happens on the line when I dial a number with an analogue phone installed parallel to the line there is two scenario:
1- CALL IS SETUP: the system pickup the line ( I hear the tic of that) and send digit ,I hear the dialed digit tone sent and the call is setup...
hi
when I had changed the LODR
ADD-LODR:11,2,,,WAITANS,3;
I had one time the dialed number is wrong from the central office and for the other times occupation tone from the CO
HELLO
YAS I HAD CHANGED THE COP SAME PROBLEM
<REG-COP:140;
REG-COP:140;
H500: AMO COP STARTED
ADD-COP:140,DTMF&SFRM&RLSA&COCN&TDED&NO1A&DITW&TIM1&NSDL&DTM1,,;
CHANGE-COP:140,COPADD,,,,INDEP,
"TMANI-DTMF-DIRECT";
BEST REGARDS
OKACHA
hello masviss
I SUSPECT A PARAMETER IN THE ZAND OR DTIM1. I THINK THAT THE HIPATH SEND THE DIALED DIGIT VERY QUICKLY BEFORE THE CO TONE AND I WANT TO CHANGE THE TIMER OF SENDING DIGIT BUT I DON'T KNOW WHERE TO CHANGE. THIS IS SOME COMMAND
<DISPLAY-DTIM1:TYPEDH=CO;
DISPLAY-DTIM1:TYPEDH=CO...
<DIS-BUEND:11;
DIS-BUEND:11;
H500: AMO BUEND STARTED
+------------------------------- FORMAT = L -----------------------------------+
| TGRP NUMBER : 11 TGRP NAME : LIGNE PRIVEE MAXIMUM NO. : 1 |...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.