OK, got this router to forward the needed traffic from the WAN to LAN. Thanks to my contacts at pandetix, I have set up forwarding so that we can monitor (my main interest in this question in the first place) and manage the BCM50e from the WWW.
From the MAIN MENU:
1. WAN/WAN IP page - check...
Wow, I am not having any success with accessing the BCM Element Manager via the WAN connection. I don't have any problems connecting to either the router or EM using the LAN side. I don't normally use the BCM50e, is there some type of forwarding that needs to be programmed on the router?
Don't forget about the EXPANSION UNIT POWER INTERRUPT issue that Nortel has with the BCM50. Remotely changing the enable/disable status as well as rebooting the main cabinet does not help this issue. You need to be onsite to physically remove power from the expansion cabinet. At some sites I...
Ace,
Unless you're using the main module. There is a, lets call it "unique," way of terminating the main module on a patch panel unless you purchase the Nortel NTAT0103 BCM50 RACK MOUNT PATCH PANEL.
The main cabinet wiring chart:
Pair 1-4: CO 61-64
Pair 5-8: Analog Extension 233-236
Pair...
I have used the EnGenius SN-920 Ultra Cordless Phone on other phone systems with good results. It has been a while, it looks like that phone model has been replace with the DuraFon 1X.
dbullion,
I think they only release the Nortel cable on confirmation of the high current problem. Otherwise you have to create your own cable using resistors. This is not applicable to echo issues.
This is from Nortel Technical Warning: 2006006589.2
If the loop length of the service to the...
That is more extreme than my experiences. Normally it’s just low volume. Luckily, every one of my sites that has received the Nortel cable has not had a repeat problem.
BCM50 Time Will Not Change
There is an interaction between the IP system and time/date change.
To resolve the problem:
1.[tab]Launch Element Manager
2.[tab]Administration->General->Service Manager
[tab][tab]Check the status of 'tmwservice' service. This is likely stopped, resulting in...
We consistently get the CO line volume due to excessive current in addition to expansion cabinets staying in "enabling". Yes, there are replacement parts and work arounds for both but each requires additional labor and cost that can't be recovered.
We have been cranking out 2 a day since the...
RYSFAN,
The Personal Call Manager is a software program that can be used to control the phone from the computer. I don't have any customers that use it but I have been playing with it at my shop with a BCM50. One of the features is it will display a screen pop for incoming calls, additionally...
It will not be seemless. If it's a BCM system any phone connected to the "remote" will have to access voice mail like an external caller. (ie the soft keys on the phone will not function.) My Nortel engineer said there would be "issues" with park and page simply because you need to be able to...
I have found that the analog extensions need hot line programmed.
Configuration
Telephony
Sets
Active Sets (Highlight the Fax DN)
Capabilities and Preferences
Preferences
Hotline
Hotline Type – External
Facility – Pool:A...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.