    polycom trio 8800 with ip office and authcode problem

    Hi We have problem about polycom trio 8800 connect ip office every well ,but when using ipoffice authcode , the trio 8800 will only show calling screen , and cannot show soft keypad that key in authization . Now the polycom is using firmware 5.9 and ip office is rel 10.1.2. How can I made...
  2. wilsontec

    Moving a G450 gateway. What are the main steps?

    When no S8300 inserted , just bustout all ds1 and station board on that gateway and then power down and move out. When have S8300 inserted , you must shutdown and backup the S8300 server first .
  3. wilsontec

    Difference between Console port and Services port?

    console port is use rs-232 port to connect service port is use ip to connect
  4. wilsontec

    EPN issue - phones do not ring - HELP!

    Do you have another alarm when display alarm ?
  5. wilsontec

    EPN issue - phones do not ring - HELP!

    HI mnealtx when pull out the power unit , use eletric torch toward see the cabinet inside pin is good or bent.
  6. wilsontec

    EPN issue - phones do not ring - HELP!

    Before replace power unit,also check the scc cabinet backplane pin is good.
  7. wilsontec

    EPN issue - phones do not ring - HELP!

    I have a case all analog card suddleny dead with power unit. We doesn't know why ?
  8. wilsontec

    EPN issue - phones do not ring - HELP!

    do you have spare tn2793b or tn 746b analog card ? You can replace one card for test good or problem
  9. wilsontec

    EPN issue - phones do not ring - HELP!

    have you check the cabinet backplane pin is good ? Because when plug in this power it may make the pin bend ? This power is old model no hz setting.
  10. wilsontec

    EPN issue - phones do not ring - HELP!

    DC power or AC Power , if AC power you should turn to 20Hz on America or 25Hz in Euro. when using DC power , it is no selectable switch.
  11. wilsontec

    EPN issue - phones do not ring - HELP!

    most of case is Power unit problem . Howerver does the message lamp flash when ringing ?
  12. wilsontec

    agent id and ia770

    Thank you The setting is add to public/private number table , I have try when the agent id trun to extension number , the voice mail can answer the call. thanks
  13. wilsontec

    agent id and ia770

    Hi we aare using cm 5.0 and call center we meet the problem agent Id assign coverage path to IA770 when 3 rings later the IA770 didn't answer the call. IA 770 is normal when office station use. Anyone know what wrong ? Thanks
  14. wilsontec

    What is the use of Signaling Group?

    it is use for config d-channel of ISDN-PRI
  15. wilsontec

    MWI not working

    I Think you must check the q-sig mwi config first
  16. wilsontec

    Definity G3 V12 - Asterisk (Freeswitch) Link

    Please try using Alaw when config E1
  17. wilsontec

    Avaya Intuity™ AUDIX® LX R1.1

    Are you using analog port for receipt call . if yes it may some parameter on port detect voice .
  18. wilsontec

    Difference between ARS and AAR

    HI as i known aar and ars is same feature , but ars always us in external call , ars always use in internal network call (e.g. uniform dialling).
  19. wilsontec

    IP Office 500 v1 - No lights

    or you can use v2 chassis power circuit replace your 500v1 power , that is the same.
  20. wilsontec

    302C Console - Mute button?

    As I remember , only can use hold button or use Headset replace your handset.