hi Born
Aspect still sell the Spectrum REN acd along with the legacy Aspect CallCentre but they are trying to push their VOIP solution. If they keep pestering you regarding VOIP just say that you want a Spectrum and that you may add VPR cards later.
In theory, theory and practice are the same...
you say that the 2 md110's are 14km apart. The network providers link will be amplified so no need for repeaters. The repeaters were only to be used in the case of a local connection.
regards
In theory, theory and practice are the same. In practice, they are not.
RFBOI
Premises Networks were the top sellers of MD110 in the uk last year I believe.
In theory, theory and practice are the same. In practice, they are not.
RFBOI
many of our customers use another ericsson partner in the uk called premises networks, have heard many good things about them,
their website is www.premisesnet.co.uk
regards RFBOI
In theory, theory and practice are the same. In practice, they are not.
RFBOI
????? there is no ethernet port on an IPU, however there is a known problem with the NIU2 where the ports lock up and the card refreshes if the V24 ports are not logged off properly before disconnecting.
In theory, theory and practice are the same. In practice, they are not.
RFBOI
I would suggest that you get IP-MUX's, and link the two over your WAN if that is not on your radio circuit.
In theory, theory and practice are the same. In practice, they are not.
RFBOI
hi Echo
the bp250 operator workstation requires 2 com ports, one from a TAU connected to the console and the other from the CPU board for integration.
In theory, theory and practice are the same. In practice, they are not.
RFBOI
Do not attempt to do this without contacting your /// partner first as it will not work.
1. Systems above BC10 are licenced therefor the IO LIM IPU will need to be reprommed with a new chip containing the site EIC number, i.e. 02-XXXX. Without this your licences will be invalid.
2. The NIU...
In the uk if you dial 142 before the number cli will not be sent for that particular call
In theory, theory and practice are the same. In practice, they are not.
RFBOI
fikyu,
you cannot get CLI on incomming analogue trunks, you need digi trunks.
kind regards
RFBOI
In theory, theory and practice are the same. In practice, they are not.
RFBOI
you need to call another isdn device to pass a call. when the vc signals out the setup chanel describes its call type, it will only connect to a similar type of device.
In theory, theory and practice are the same. In practice, they are not.
RFBOI
each lim can have its own tmu which can be used for moh, therefore each lim can have its own music source, but generally the music source is daisy chained across from lim to lim. you must be take care for different customers music sources as if a digital route is shared it will take the music...
As far as I am aware the only DT3xx phone to work on MD110 integrated DECT is the DT368, as the integrated DECT is GAP2 (CAP), provided the appropriate firmware is loaded.
Hi MDsup
try these settings for MD110 to MD110 Qsig
ROCAI:ROU=X,SIG=111100000031,BCAP=11111,TRAF=00151511,SERV=2110030000,SEL=013000000000,TRM=5;
(A END)
RODAI:ROU=X,TYPE=SL60,VARC=00000310,VARI=05400000,VARO=02200000;
(B END)
RODAI:ROU=X,TYPE=SL60,VARC=00000310,VARI=05400000,VARO=02000000...