Hi all,
Most likely my last post on this forum (*sniff*), and one final request for help if possible.....
As the corporate wheel in my company turns ever forward, so too the voice system we used has been superseeded by, ahem, a Cisco VoIP solution...(apologies to those of you offended by the...
Hi everyone,
Is there a way to dial in to collect voicemail from an external number on a option 11 24.25, with standard Mermail (not sure of version) ?
The DN itself has since been moved over to a different PBX, but there is still some messages on the old mailbox/PBX.
What I was hoping was...
Hi,
Has anyone had failures where 2616 sets get disabled on NT8DO2GA cards ?
We have the situation (shown below) occur once every couple of months - for no apparent reason. The 2616 sets are all plugged in, so they are not disabling as part of the overnight LD60 TN sweep.
The only point to...
Thanks for all the info guys - apparently the legal issues are covered, so I'm just "doin' what I been told"... ;)
The solution in the end is very low-tech. I have bought a device to connect between the attendant console and the headset, and the receptionist can just hits the record button and...
Hi everyone,
I was wondering if anyone has experience in activating MCT on an option 11.
Specifically, I would like to be able to extend the MCT functionality to record the *actual voice* when the TRC button is hit, eg: receptionist receives malicious call, hits TRC on attendant console...
Hi,
Fairly new to this forum - normally involved in Meridian Telco space but was hoping someone may have run into a similar scenario here.
Based in the UK, I would like to terminate an E1/q931 circuit onto a cisco 3640, and use this to route voice calls to and from a PBX.
Current set-up:
PBX...
Hi Colin,
In the UK.
I do have a slightly higher level I would guess as I've configured SPN's, RLB's, trunks, CDP's, etc as well as all standard set administration.
Off hand I can't actually remember the overlays I wasn't able to gain access to, but before jumping ahead into the world of...
Hi,
I currently administer two Option 11's, and have had little bother doing whatever tasks I needed. However, from time to time I have a problem with access to certain OVLY's. This I would guess is due to the user access level (or whatever it's referred to in Meridian speak) on my current...
Hi,
Using Option 11 24.25 with meridian mail (can't remember the revision off hand) and have been asked if I can copy off some voicemails left on a certain DN for evidence in a disciplinary, but I can't think of any 'easy' way to do it.
Is there some kind of serial interface I can use to...
Thanks for the info. I will swap out the card as soon as I can get some downtime.
To confirm though - are saying you should be able to program as many SCR/SCN keys on 2616 phones as you want without causing any effect to the loading of the line card ?
Also - does anyone have any more info on...
Hi,
I'm looking for a better way to manage some 2616 digital sets on our option 11 system. Currently 3 company directors have their direct lines mapped to key 00 as the SCR , and the numbers of the other 2 mapped as key 03 SCN, and key 04 SCN.
The problem is, whenever one of them is on the...
There is a gui called 'phonemaster', the company are based in Ireland.
If you persist a little with the CLI you can obtain all the info you need, eg : trunk details, phone details, etc. I don't know how familiar you are with the CLI but it took me a good few weeks to get my head around it (I...
thanks for the info guys...
any idea on why the line gives a 'dead' signal though? have the impression i'm just missing something obvious but would have thought it would be 'busy' signal or something.
Cheers,
P
Hi all,
Scenario:
Meridian option 11, 2616 phone has CFW set to main reception attendant console (2250).
Call comes in on 2616 number and forwards straight away to reception, operator bounces call back to dialled number as person is at desk, just screening calls thru reception first, line...
Hiya,
Does anyone know a way to greatly increase the earpiece volume (like, way above what we're getting by using the 'slider' below the keypad) on an attendant 2250 console ?
If you speak to someone they can hear you clear as a bell, but you can hardly hear them.
Have tried the obvious:
-...
Hiya,
I have 2 x 2250's at seperate sites using option 11. One is the 'Main' switchboard number (for our distribution centre), the other is the head office reception (secondary number).
The two sites are joined via TIE trunks using a coordinated dialing plan (distant steering code) to route...
Hey 1911....
I figured as much with regards to the proprietary use of this port - but surely serial comms is serial comms? Even if you can't do much with the output, I would have thought standard connections should still produce *something* ??
In any event, boss has decided to fork out and buy...
Do you want use VOIP across a single site - or use VOIP to *link* sites - say, siteA to siteB, with standard Option 11 PBX's at either end ? (Just that you mentioned multiple option 11s in the first post!)
Second option does not make use of VOIP in terms of structured (cat5, etc) cabling on...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.