Hello Friends,
Recently I faced java runtime error while trying to do anything through openscape 4000 assistant web portal. It shows java license validity period is over. Here I enclosed screen shoot of the error. Please see the attachment and suggest me what should I do now to solved the...
Dear Sbcsu,
Yes this is new install. Hope you can remember earlier you helped me for configure STMIX Q2343-X Board. I configured the same as you suggested. We are using STMIX Board for HG3550, HG3530, SIP, and SLMAV for TDM Phone.
Regards
Dear All,
I’m getting one side voice in HFA phone. System platform is Unify Eco Server Openscape 4000 V.8 R.22.
The problem is like:
HFA User to HFA User:
One user can hear both side voice and opposite user can hear his own voice only.
From HFA User to TDM User or from TDM User to HFA User...
In STMIX board, I added total 72 IP phone user.
From them
4 are physical SIP phone
8 are SIP soft phone
Both are working (Incoming and outbound calls tested)
And 60 HFA phone which is not working (as I send you error message before.
Also there are 2 AC WIN SL which is also not working.(Showing...
Hi,
Its just Openscape 60 HFA Phone.
I added user like:
DISPLAY-SBCSU:STNO=4588;
H500: AMO SBCSU STARTED
----------------------------- USER DATA ----------------------------------------
STNO =4588 OPT...
Yes I Updated it from RMX
am troubling you lots. Actually I worked till Hipath 4000 V.2 and this one is totally new for me. What ever I added HFA User (SBCSU) and SIP trunk (TDCSU) but can't configure Openscape 60 HFA phone set. there is a manual inside the box but nothing is there.
Can you...
Hi,
Now 4000 Assistant can login. Thanks a lot for your support. can you please tell me what is the ip address should i put for:
CHANGE-CGWB:CGW,3,1,MANLANIF,0.0.0.0,0.0.0.0,NO,0,0.0.0.0;
Regards
Hi,
here is the details
REG-CGWB;
H500: AMO CGWB STARTED
ADD-CGWB:3,1,NORMAL,192.168.100.15,255.255.255.0;
CHANGE-CGWB:CGW,3,1,GLOBIF,,,213,NO,0,192.168.100.1,4060,AUTONEG,0,0,10,0,4061,192.168.0.5,192.168.0.6,NO,0.0.0.0,5060,5061;
CHANGE-CGWB:CGW,3,1,SERVIF,"TRM","HICOM"...
Hi Dear,
Thanks for your solutions. delay issue are solved.
I tried to ADD CGWB as per your sample data
ADD-CGWB:3,1,NORMAL,192.168.100.15,255.255.255;
But when I tried to change CGWB WBMDATA its ask password like
CHANGE-CGWB:CGW,3,1,WBMDATA,"HP4K-DEVEL",,ENGR;
H500: AMO CGWB STARTED
F11...
Hi thanks for your support. Yes now I can access and make outgoing PSTN calls. Actually the PSTN line I was connected that one have no outgoing facility. So I change the PSTN line and calls are passing now. But after completing dial getting delay(near about 30_35 second) ringback tone.
Can you...
Hi;
I change as per you suggest but till call not passing: here is the details of trunk related configuration please check and help me to solved the issue.
<DISPLAY-BUEND:TGRP=1,FORMAT=L;
DISPLAY-BUEND:TGRP=1,FORMAT=L;
H500: AMO BUEND STARTED...
Hi Dear,
Please ignore my earlier post there are little bit typing mistake.
I tried to make a dial plan but can't success. My problem is call not passing through PSTN line. I have 2 LDPLN (9-Z and 81-X)for same route.
when using DPLN 9-Z
getting busy tone after dial the complete number (like...
Hi Dear,
I tried to make a dial plan but can't success. My problem is call not passing through PSTN line. I have 2 LDPLN (9-X and 81-Z)for same route.
when using DPLN 9-X
getting busy tone when dial any digit after 9.
when using DPLN 81-Z
getting busy tone after dial the complete number...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.