You have ruled out the phones , can the phones be called by other phones on site to verify the extensions are the correct ones for the rooms . Did you check programming to insure they have the correct tenant ?
Have tested and verified these symptoms yourself . What trouble shooting steps have you taken if you verified symptoms . It could be as simple as a bad analog set or a split pair at the halftap with another port .
I had been working on the Mitel line of PBX since the early 1980's . I liked their switches all the way thru the 2000 dark & light . When they brought out the 3300 , that's when I started to plan my retirement . It is very difficult to maintain if you cannot have access to the network it resides...