We cannot make outbound calls but are able to receive only.The internal extensions are working fine.There is dial tone available but upon dialing number there is nothing whatsoever.
How can I check that the trunks are ok on our side before we call the service provider? We use IPS 2000 with...
Thanks OzzieG. I have followed your suggestion and problem solved.I have decided to follow your pattern for the working auth codes as well for simplicity. [shadeshappy]
Many Many thanks for your help OzzieG.Really appreciate it.
Ariku.
Hi Ozzie,
This is what I have for the following autority codes using CMD 2A00 and 2A10.
2A00>2904:0739
2A10>0739:1 working perfectly
2A00>2905:2123
2A10>2123:3 does not work.
2A00>2468:0610
2A10>0610:3 does not work
2A00>2222:NONE does not work
The 2nd Data in CMD2A10...
Authority code. I have been using a call accounting program(CAAB Ti)to allocate authority codes to a few of our admin users for outbound call access-unrestricted.The rest of the phones are partially restricted (code 55)-local only.
The problem I have been having for the past few months is that...
I did! Actually I had entered new data after pressing F2 in MOC-and there was no response. But it should be the other way around!!
Now its working!!Thanks OzzieGeorge. Thank you for the walk thru.
You're great!!!
And for those who give tips occasionally full marks to you all!
I have learned a...
Pressing [EXE] does not give me OK (in MOC)to enable data entry.
This is the assignment procedure I'm following.
[ST]+CMD code+[DE]+First data+[DE]+second data+[EXE]
Am I missing something? Or is there another way to set the data?
Thanks.
Ariku.
Thanks OzzieGeorge.
This is what I've got with y=0. There is no data for y=2,3
COMMAND=200
200>0
200>0:A126-
200>1:100-
200>2:803-
200>3:803-
200>4:803-
200>5:NONE-
200>6:NONE-
200>7:NONE-
200>8:NONE-
200>9:800-
I can see that 1 is set for trunk route, 2-4 for 3 digit station and 9 for...
Can someone explain and point me to right direction?
We have a mobile number programmed for system speed dialing on a ips2000.The number can be called from any station. The system has stopped working.I have tried from my Dterm but cannot get through.
Using CMD720 this is what I get...
Problem solved! You were correct OzzieGeorge. I had not realized that the handset socket was at the opposite side of the phone! Someone had to point it out the other day when I mentioned the problem to my colleagues. The phones are working fine now.
Many thanks.
Ariku.
I have a couple of refurbished Leader1026HS and would like to use them on our NEC IPS 2000 pabx.The problem is I do not get a dial tone when they're connected. You can be able to ring other stations but you cannot hear anything on both ends.
Is it possible to make them work on our system and if...
Thanks Tstelecom for the info. It sure is a bit confusing when you have to move between different commands -and each command relying on yet another command.. My problem is finally solved.Our contractor checked and verified that our trunk was open. And upon checking with the telco we were...
Thank you belevedere for your suggestions, and you're correct, LCR and Toll restriction are not straight forward to program as I thought.
The trunk restriction class in CM1201 are set to 55(semirestrict) for office stations, they were working fine. Anyone could dial 0 and be able to make an...
Hi,
I am a regular visit to the forum and have learned alot from the forum-you guys are great.
This is my problem. I have been trying to set authority codes for our system and was playing around with the service restriction class.
from 15401>15:7 set to 15401>15:0 to allow for authorization...
I am a newcomer to the forum and I think this site is the best I've seen so far..excellent!!.I am tasked to keep our pabx system going but I don't have much experience in programming.I have a NEAX IPS 2000 dropping off incoming calls on the DTerm seies handsets. Any idea on what is happening and...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.