Hello,
I have configured MG SIP for the SIP trunk between Cisco CM and NEc Sv9500, presenlty i am facing a issue to make an outgoing call from Cisco,which should seize PRI trunk (routeRT120) from NEC(but local calls are going trough Route 21),problem with National calls,which is not going...
Hello everyone,
wants to know which is the command to show extension number on display when the phone is idle.
i can see the extension number when i pick up the handset.
kindly check if the welcome message exists?
1.press speaker
2.Press 716
3.press 5
4.it will ask for the message number(3digit message number)
then it will play the message.
or may be system is gone to night mode, change it to day mode.
command:
1. 14-07 for access map 2, make trunk 2=7(outgoing and incoming) and rest of the trunks make it Zero.
2. 15-06 for station 114 give the access map 2 in all the trunks.
in this scenario, 114 will access second line always.
command
1. 22-05 for trunk 2 make set the data as 2 in all the modes
2. 22-04 incoming group 2 set the station 114.
so you will receive the call for second line in station 114.
Thank you for sharing this information, its very useful.
But here in my scenario, i used meet me conference feature and it worked, every time they make a call they should transfer a call to the meet me conference pilot number.
anyway its resolved my issue,thanks for your support.
Hello,
I have connected a Polycom sound station with SV8300 as a third party SIP, i am not able to make a conference call from this.
I am following the below procedure:
1.make a call, once the call is answered
2.press conference button
3.make a new call, once the call is answered
4.press again...
Thanks Belvedere, i have done all these programs.
my PRI line is in the main site, calls are going via main site from remote site, there is a outgoing call details, even incoming call details are available on smdr tool, but it doesn't give extension number, it gives ccis route and trunk route...
Hello Guys,
i have SV8300 systems working on CCIS over IP:
Site A is a main office with PRI line connected and Centralized Billing (ma4000) is working.
Site B is a remote site .
Site B is receiving a call from PRI, but i can not see the incoming calls on the smdr tool, or ma4000. but i can...