Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations SkipVought on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. StinkTech

    Issues adding Asterisk box to Option11c System

    Option11c timing is set to EXT I've tried to change the DCH CLOK to INT but cannot get the Option11c to prompt the CLOK prompt when doing a change. ADAN DCH 13 CTYP TMDI CARD 05 PORT 1 DES ASTERIX USR PRI DCHL 5 OTBF 32 PAGE 003 PARM RS232 DTE DRAT 64KC CLOK EXT...
  2. StinkTech

    Option11c TIE PRI to Asterisk

    Connecting an Asterisk box to an Opttion11c via a TIE PRI. The Option11c has 2 PRI's from AT&T and a TIE PRI to the Asterisk Box. The Asterisk Box has a PRI from Windstream. Have call routing between the two working but cannot figure out the timing setup of the TIE PRI to the Asterisk box to...
  3. StinkTech

    Issues adding Asterisk box to Option11c System

    Asterisk box has two T1 connections. 1. PRI from AT&T (AT&T provides clocking on this circuit) TelcoB(M)--(NI2)--(C)[SPan1]Asterisk 2. PRI to Option11c (Asterisk provides clocking on ths circuit) Asterisk[Span2](M)--(Q.SIG)--(C)[Loop5]Option11c On the PRI to the Option11c even...
  4. StinkTech

    Issues adding Asterisk box to Option11c System

    Changed DDB settings to stop maintenance counters from restarting loop5 due to SLIPD hits but I'm still taking the hits... In a scenerio with two circuit providers how do you setup clocking on the Option11c? Thanks... StinkTech
  5. StinkTech

    Issues adding Asterisk box to Option11c System

    All call paths seem to work fine when the link between the Asterisk Box and the Option11c is UP but the issue I'm having is the link keeps bouncing. I believe it's a clocking issue. I have two PRI Providers. The Option11c's Loop5 SLIPD counter is incrementing. Setup configuration below...
  6. StinkTech

    External Ringer Problem

    FYI: Disconnected the ringer and the line stayed busy... Moved to another card. Working fine for the last couple hours. Thanks...
  7. StinkTech

    External Ringer Problem

    No...What would that tell me?
  8. StinkTech

    External Ringer Problem

    I've got 6 Digial phones (4x2616 and 2xM3904) and one analog (1x500) with a MCR DN 2000 setup as a ring group. The analog line is connected to a ringer. The problem I'm having is the ringer will work 10-20 times then stay busy and no longer work. The digital phones continue to ring. If I...
  9. StinkTech

    PRI SETUP, Can Receive all, only tollfree calls go out others rng busy

    Called the LEC back to verify the circuit settings. 2 Hrs laters started working...LEC never called back. Hum... Thanks...
  10. StinkTech

    PRI SETUP, Can Receive all, only tollfree calls go out others rng busy

    janaya, this is a rebuild of a system hit by lightning. Nothing changed on the LEC side. We were not removing the 1 prior. Plus we can not make local calls either (10 digit dialing). Again everything goes out the same rli/route with no DMI. thanks for the prompt response...
  11. StinkTech

    PRI SETUP, Can Receive all, only tollfree calls go out others rng busy

    PRI SETUP, Can Receive all, only tollfree calls go out others rng busy (fast busy). DCH monitor shows CAUSE: #41 - NTWK TEMP FAIL Can dial toll free numbers ok, incoming works fine all others fail. LD 90 AC1 routes all tollfree and others to same rli (2) no DMI all out the same route (0)...
  12. StinkTech

    Replacing Processor Card

    I've got a customer with a Legend Magic Rel7.0 A lightning storm took out the programming port. I've picked up another processor Rel7.0 processor card. I'm thinking I should be able to put the 2mb flash card in the new processor card restart the system and all should be good. Is this...
  13. StinkTech

    CP 150 Fails

    Curlycord, Even though your site is under construction I still enjoyed it. It was on a different network prior. I plan on taking a new Powersupply up in a couple weeks. I'll see what happens. Thanks for the input. BTW: Where are your FAQS? Thanks, StinkTech
  14. StinkTech

    CP 150 Fails

    gforce, Don't know what version. I looked but all I can remember is the year on the sw card 2004. I've left the site. I will be back there in a couple weeks when the circuit gets put in. I hope to have a game plan by then. Below is another capture from the serial port. Thanks...
  15. StinkTech

    CP 150 Fails

    All lights cycle. After awhile all 4 lights on the left are light up. No lights on the right. I have a new 8 volt powersupply. I've reseated the software card. I can ping the IP but cannot access the cp mgr. Even though the network light is not lite on the cp it still lights up the switch...
  16. StinkTech

    LM Manager

    CCMS 6, LM Service failed on a new install after installing SU_07. I uninstalled the LM and reinstalled. When I go to view the licenses in LM Configuration I get the following message: CC Licenses: No Active License Manager After browsing and importing the license key file restarting the...
  17. StinkTech

    Script Variables fail to add

    Back in early 2009 I had two servers built up without configuring them so we would have a standby ready. I guess I forgot the password used at that time. Thanks...
  18. StinkTech

    Script Variables fail to add

    It looks like it was a permissions issue. I reset all the passwords (sysadmin, NGenDist, NGenSys & NGenDesign) restarted and all is well. Thanks...
  19. StinkTech

    Script Variables fail to add

    Updated to SU_07 still no joy...

Part and Inventory Search

Back
Top