Hi,
In the Call Pilot Manager, in the Mailbox number...I put 000000 as default and the password is 124578.
In the Server field, in the "Preset server list" I select "Enter data manually" and after that I put in the server field "localhost".
But I can´t login, the screen show me "Error on...
Johnpoole, But in this old software Is It possible to route calls depending on the digits dialed (select different routs) If It´s so, could please tell me the LD´s and prompts That I need
I want to use BARS/NARS because I installed a new DTI2 with a Carrier but the carrier doesn´t give me dial tone when I take tha Rout, Is there a way to make the Meridian generate a dial tone?
I`ve got a Meridian 51 with release 16, The BARS/NARS programming It`s the same for this release I mean:
LD 86 --- ESN
LD 90 --- NET
LD 86 --- RLB
LD 86 --- DGT
Why when I install a conf/TDS card in a option 51 in slot 2 this card takes slot 2 and 3 as follow:
when in CFN in CEQU ask me for slot for XCT I put 2 then It puts automatically:
TDS 2 conf *3 mfsd *3
And slot from 1 to 8 in CPU/network shelf become:
1 apperas in programming as 1
2 apperas...
ok...I didn´t see in LD 97, and problebly there is card programm in slots 5,6 or 7, Maybe, Is This the reason because I can´t define any card in slot 5,6,7(Give me error SCH0535 that tells me that there is a loop card there)?
Why when I programm the conf/TDS card in CEQU(LD 17):
XCT 2
It takes...
I´ve got an old option 51, I´m trying to install a Dual DTI2 Card (NT5D97AD), When I print the CFN en LD 22 It shows that I´ve got the following configuration en CEQU:
SUPL 04 08
XLT 02
TDS *02
CONF *03
MFSD *02
In the 51 manual tells that the CPU/Netwotk module has 8 slots for Network-type...
Hi all,
I was trying to move a QSDI card in a Meridian 51, from slot 9 to 8. First I disabled the card using the enb/dis switch, then i insert the card in slot 8, and i put the switch in enable mode. However the card remains disable. What are the steps involve to enable the card?. Is there any...
I`ve got the following card in core/net module:
slot 14: Omega FN
slot 15: Omega IF
slot 16: OCMA
slot 17: Omega 768KMEM
slot 18: MDU
What was the last release for option 51. The customer send me this information but I dont know what the PBX´s release
I need to connect a CC card QPC775 and I´ve got an old manual that tells that in a option 51 the CC is connected in slot 9 in Network module and the 51c in slot 8 core/net. I think that the PBX It´s a 51c because It´s has ENET cards in the core/net (in option 51 the core and network were in...
I´ve got to install a New 2.048MB Dual DTI2 NT5D97AD on a 51 option, This card already has ENET imcluded, but Does it also require a CC card? I've got an old CC QPC775C Card, These two cards can work together (compatible)?
I´ve got a 51c and I want to install a 2.48Mbit (QPC536)DTI card, This Card needs a CC (QPC775C), the CC has to be install in slot 9 in the core/net shelf, But now in slot 9 there is a QSDI (QPC841C), can I move the QSDI card to another slot and where I programm the QSDI card (Or this card...
johnpoole
Before installing the IVR I had just a Symposium for serving the incomning calls from a DID number and analogs lines, Now symposium was replaced by the IVR that gives the information to the Callers (as mention above the IVR and the PBX are linked through DTI2 programming as TIE in...
John Pole
When I dial the ACD (the acd in NCFW has the CDP tha goes to IVR), the PBX sends the above message and the IVR doesn´t answer (The Link between the PBX and the IVR is TIE R2MFC), I Think The ACD is sending DTMF tones and Link rejects, Can I program the ATDN in a trunk to be a HOT D 4
Hi
I`ve got a connection again an IVR,The link is a DTI2Mb card programming in TIE mode R2MFC, I've a CDP within DID numbering plan that goes to IVR and the IVR receive calls from the number trough a DTI2 program as DID, Now I want analog line (from DXUT card) to go to the IVR but I can´t...