Answering your the initial question, you cannot cover the same call twice. Once it is already covered, it will never follow the coverage of any other object.
Exactly. Unfortunately the implications are tremendous: besides the fact a solution cannot be tested internally without preparation, calls arriving on different trunks may select different ARS tables, also there are the internally transferred, covered, forwarded, etc scenarios if you want to be...
VDNs will use the ARS/AAR table that matches the caller's location. For incoming trunk callers it is the trunk's location (location of MG for legacy trunks, location assigned to far-end NR in signaling group for IP trunks). In case the trunk has an empty location ARS/AAR table, it will use the...
According to ACD guide: route-to with coverage=y command behaves like a directly dialed call instead of a VDN call. Therefore the terminating station's display only shows the originating station's display information and does not show the VDN information.
Cannot test it now, but worth a try though.
Hi,
you can use the built in modem, only need to attach the 25th port from AUX (if I remember well of its name; it is the first cable coming from the cabinet) to an analog line.
Cheers,
SzuperK
Thank you so much WillKoo!
Altough I need to use different slot (different cabinet number) because of a MCC1-G650 migration. Sometimes somehow I should try whether it is working with typing in different slot numbers in "change announcements".
Hi all,
I would like to use the announcement boards from an old system in a new one, with all the recordings on it. Is it enought to pull out these cards from the old system and put them in the new one? (Should all the announcements show up in "change announcements" field, or I need to import...
Hi all,
Does anybody know why the G700 MIBs disappeared from new releases on support.avaya.com?
I would like to monitor VoIP resources, but my SMNP client alerts that the older MIBs are corrupted... Does anybody have a working scenario? Or could someone tell me the OID range of G700 voip...
Hi Guys,
Many of the denial events refer in Event Data 1 to the UID, which as I know is a specific number for each entity in the system. My question is how could I interpret these for better maintenance?
Any suggestion is greatly appreciated.
Cheers,
SzuperK
Hi all,
I have the following denial event when trying to transfer outside the PBX:
1761 Transfer COR restrict
Evt. Data 1: 5DDE
Evt. Data 2: 10
Could anybody help what could cause the problem? The trunk COR setting is allowed for calling. What do the event data fields mean?
Thanks in...
Hi group,
I have a problem that INADS ext is calling somewhy the attendant. Could you please help me to solve this problem? (Where to set a different number, or disable it)
Thanks and best regards,
SzuperK
Hi,
on "change system-parameters cdr" form enable option "intra-switch CDR", then after entering "change intra-switch-cdr" you can fill the extension you wish to appear in the accounting system.
regards,
SzuperK
Thanks a lot guys, I tried a reset sys 2 and it was enough.
Anybody has a documentation about a detailed reset levels? (what kind of services effected, etc.)
Hi all!
Anybody has a procedure to force the G700 LSP to re-register after a broken link to the main site? (main site is G700 S8300 also)
Best regards,
SzuperK
Hi all,
Have no system to test it, but I would like to configure phone sets to see whether a message arrives to a particular mailbox. Is there a way to accomplish this?
Thanks in advance,
SzuperK