No chance. You can only ask someone who the other password. hicom is the highest level in standard. If it´s changed there is no way to override it. In that case alredy systems will be generated complete new from a empty harddisk. If you have the right to execute the amo regen, mayby you have...
I know the problem with delayed MWI to. I know also 1 system with this problems. Most times we had this problem not with expression, because I don´t support it, but with SpeechDesign Memo. I´m not sure thate the problem is located in the HiPath, because we have no problems with the Siemens/Rolm...
Thera are only a few gys the can read the trace without a translator. So I show respect only for youre trying.
Message doctor is a old toll, the newer one is WinWisu. But also WinVisu is discontinued, because the real time diagnostic system of the HiPath 4000 includes a translator. Both tools...
Why it calls Atlantic, iI don't know. But I know, that the Atlantic-LAN is the internal LAN of a Hicom 300 E and a HiPath 4000. Over this LAN works the communication between the processor-boards. It has fixed IP-Adresses in the net 192.0.2.0 . Thera are the SWU A with 192.0.2.1 , the SWU B with...
It must run over Siemens, becaus you need new codewords for youre licensing. Mayby some boards will not run on HiPath 4000, for example the WAML-Board in HiPath 4000 V2.0. We have also problems with the TMOM-Connection for paging-systems. I think, the first generation of SLC16-Boards will also...
That is a large count of points, where it can blocked. Is the acces-code to the second E1 in the AMO WABE in traffic-situation 6 administrated?
Is in the main-part of the AMO ZAND a connection from trunk to trunk allowed?
Has the first E1 the rigth (COS, LCOSS, LCOSD) to acess the second E1...
There are much more differents between the systems. At first, there are 3 Systems of the Hicom 300 -Family.
Hicom 300 (16 Subscribers on board, no licensing)
Hicom 300 E (24-subscribers on board - most 16-boars will run, licensing)
HiPath 4000 (like 300 E, but new boxes for rack-mounting, new...
I guess via RS232! CTRL-T , then you get back the question login= followed from a the input-character (heart). You have to enter youre inputs with CTRL-C, not with CR.
Bye
Niels
Why you don´t run the macro directly on the PBX? There you call also start morer then one AMO by using a command-file. You crate the file and transfer it to the PBX (I think the best ist the :PAS: for that). Then you enter in the AMO CRON not a command-line. For that you take the file-name...
It must work! You need at first a correct routing to the XPression from booth systems. Exspeccilly the global acces-code must be reachable from both systems. Then needs the COT of the trunks beetween the systems a flag for transport of the MWI-indication. Then you need in booth systems the same...
We have in oure company one SCCA. In other case it will be possible to lose the partnership-contract wit Siemens.
But, this certification is a joke. Most questions are not relatet to the HiPtah. There is a very high part of network-basic, expecially TCP/IP-questions. But you don´t have to...
I guess, it will be only possible with a external application. Look at www.estos.de , there you can find a good tapi-driver for the Hicom-systems. There you will find also a lot of aplications. With the procall-application it is possible to make selective call-diversions. With that you can...