  1. nortek

    MICS DR 6.1 and DTI cards

    I've got a customer that has a MICS w/ DR6.1. The T-1 in it is a point to point hooked to another MICS w/ DR 6.1. They are having some major issues with the T-1 and I might need to replace the DTI card. Can I replace the T-1 card (#NT7B74AAAA) with an older one? Or does it have to have the newer...
  2. nortek

    Auto Attendant on Meridian Mail

    I had a request from a customer today and I'm not sure this can be done. It's on an Option 51 w/ Mer. Mail. Right now they have a main number coming in on a T-1. Calls ring in dirrectly to auto attendant and then transfer out to extensions or the operator. No DID's or anything special. Is there...
  3. nortek

    Outgoing Call Timeout

    Another thing you can look at is Interdigit Timeout. It specifies how long the ICS will wait between user dialed digits. It's programmed in Routing Services. Nortek
  4. nortek

    9 Digit absorb

    That's what I was thinking.. set up the route and enter the dial out digit as "9", this will enter the "9" automatically after the centrex line is accessed. Nortek
  5. nortek

    T7000 phones???

    Their probably just looking for the "T" series(ie. 7100, 7208, 7316)
  6. nortek

    Networking Norstars via T-1

    I've got 3 sites w/ MCK's. They work great but now that they've been bought out by some new company advance replacement is near impossible to get without some kind of mait. contract with them. They are really trying to make it hard to work with them. Of the 10 MCK's i have installed in the last...
  7. nortek

    DR5 version has Disconnect Supervision?

    It will make a BIG difference if you have voicemail. Nothing like having 2 lines "hang" open and you've only got 4 to call out with!!
  8. nortek

    Forward calls to external #

    I had a 6.0 MICS, inbound calls came in on 8 channels of a T1 and outbound are on 6 copper lines. I set up routing for local and long distance. Used the call forward feature and just put a 9 in front of the number. Call was routed everytime the extension waas called.
  9. nortek

    CP100 Question -> Guest Mbox

    The key is that there isn't an extension tied to the mailbox. The phone system is tied to the voicemail but they are two seperate machines. An easy way to get around this without needing a phone is to make extension 3000 an analog port and in Capabilities set the call forward no answer to the...
  10. nortek

    Networking Norstars via T-1

    I know for sure you can do the overhead paing. I've got two sites with 6.0 tied with a point to point T-1. I did the programming through line pool accesds codes to open the T-1, an auto answer DN and page code on the far end. THey only use it one direction (out to a plant).
  11. nortek

    NT5B01 How to tell if this has DS?

    Normally it would say DS on the inside of the cabinet and most of the times that I've seen it there is a red or green dot as well.
  12. nortek

    External Call Forward on Call Pilot 100

    6.1 on the KSU and I didn't catch the CP100. I think it was 1.5 something. They are using 8 channels on the T-1 card and 8 lines on 8 LS/DS ports. DS is programmed. I tried 12 different combinations in CCR and even tried using a line to call out on with an appearance on a phone so I could...
  13. nortek

    How do I p/up an incoming call from non ringing economy handset

    If the phone is hooked up to an ATA, you could try programming the port to be in the same pickup group as the phone you are trying to pickup and then hit *75 or *76 and the extension to be picked up. Make sure the analog phone port is primed to internal dialtone. I can't say this will work for...
  14. nortek

    Battery for 616

    The battery holds the programming when the plug is pulled. You can do a search on google and pull up 3 or 4 websites that sell the batteries.
  15. nortek

    External Call Forward on Call Pilot 100

    I tried the "D" but still didn't hear dialtone. I'll try the "*". Thanks.
  16. nortek

    External Call Forward on Call Pilot 100

    Routing is set up in the KSU. They dial 9 for all calls. There are also 2 line pools "A" access is 812 and "B" access is 813. Why these numbers were used I don't know. I used the "route" option and put the 9 in front of the number but I got the numbered dialed (I could hear it) but then I got a...
  17. nortek

    External Call Forward on Call Pilot 100

    Can anyone give me some instruction or any hidden tips to get this working. I need to set up in CCR so that when the caller presses a certain key they are forwarded out to a toll free number. I tried to set it up but everytime I checked it the call pilot would say that the routing wasn't correct...