Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations SkipVought on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. robbot

    Branch Office and SIP

    Yes, I have tried a lot of combinations. I can force the call up the VTRK to the NRS but get it rejected. On the NRS I have tried this config: Service Domain = customer.com L1 domain = myCompany.com L0 domain = MyCDPDomain Enpoints = siteA and siteB and Service Domain = customer.com L1...
  2. robbot

    Branch Office and SIP

    Hi, 1. Yes it is 2. Idle reg'd 3. The SBO is defined with the MO in Gateway endpoints 4. Can't do IP at MO to TDM on SBO, will try SBO TDM to MO IP tomorrow I am now pretty sure it is call types (SBO dials AC1 + XXX, = AC2 + ZDP + XXX and NRS is not understanding it), I wasn't sure if the SBO...
  3. robbot

    Branch Office and SIP

    I am trying to get SIP trunking to work between a MO and SBO. I can route the call from the SBO local exchange to the MO but can't route it back up to the SBO. The ZDP/RLB/DMI etc are all OK, but the call never hits the Vtrk Dch - even when I force it with an acod.. Anyone had this or can...
  4. robbot

    Secure Modems for PBX

    Hi, you can use a US robotics courier modem. That supports remote and local passwords. only 8 characters though, but it is case sensitive. you can set it for both remote and local passwords Cheaper than £800 too.
  5. robbot

    OPT 61c upgradable to CP PII possible?

    YES it can. A 61c to PII upgrade is supported as long as you go to Rls 3 software. The D and E cables are required to allow the both half groups to communicate not for the CPUs. (The PII card cages has the provision for the D & E cables) The PII CPU's only sync through the LAN. I have just...
  6. robbot

    OPT 61c upgradable to CP PII possible?

    I know about MG/SG but like I said I wouldn't want to as a 61 is a 1 group switch (refering to FNF). My question was can a 61 be upgraded to a CP PII 1 group (i.e. are the D and E cables the same to connect the buses, etc). According to MERL3 it is not supported unless it is a 61/61c to 81c...
  7. robbot

    OPT 61c upgradable to CP PII possible?

    Is it possible to upgrade a 61c CP2 to 61c CP PII without FNF? I know the upgrade is supported for a 61/61c to 81c PII with FNF as it says so in the NTP's but no reference to keeping it a 61c. I know that there is not much point either - I mean buying a super CPU for a 1 group switch and all...
  8. robbot

    BCM to Meridian interworking not working

    Nortel gave us an upgrade for free anyway... I wonder if all you guys got it working in the US using T1 1.5Mb? I am in UK and using EI 2Mb..
  9. robbot

    BCM to Meridian interworking not working

    Yes, tried all that. it is an issue with the s/w. Like I said Nortel are upgrading for free (61c 22.46 - rl3) as they made a mistake... well for sl1 anyway needs 25.40 or later..
  10. robbot

    BCM to Meridian interworking not working

    SL1 won't work unless it is 25.40 or higher. if you try, with either a DCHI or MSDL on lower software you will get BC errors. Works straight away if you have the right software level. I had to use a Mini instead.. Nortel told me it would work and it didn't so they are footing the bill for the...
  11. robbot

    Upgrade to Succession 3.0. ITG card question

    You can configure the ITG without OTM by taking the flash card off the card and putting in your laptop if you need to (corruption or you can't/don't have OTM) It is much, much easier if you have OTM as you need to know what you are doing. ITG expert guide required. I did it once but it was a...
  12. robbot

    BCM to Meridian interworking not working

    This is a problem for calls coming into the M1, not out. I can call out so the TGAR/NCOS are fine. PRI214 is a layer 1 protocol error - fix is to call tech support :( I am wondering if there is a patch or it won't work with a DCHI card and needs an MSDL. I got this working with an opt11 on...
  13. robbot

    BCM to Meridian interworking not working

    Hi, the route/trunk is programmed as a tie. I am sending 9123 from the BCM to route out from the M1 to the CO, 123 is the speaking clock in the UK. All other numbers are the same (PSTN and local DN's). Can dial them locally (on M1) but can't send them from the BCM.
  14. robbot

    BCM to Meridian interworking not working

    Hi, I know that BCM to M1 is possible using SL1. I have implemented it on a RLS 22.46 opt61 and can only make calls from the M1 to the BCM but not the other way. When I try to call I get the following message: PRI214 DCH: 13 DATA: 00000003 PROGRESS: ORIG ADDR IS NOT ISDN CALLED #:9123...
  15. robbot

    CIU power pins

    Thanks for that.. I have it from ascom (finally) that these are the pins below. The CIU takes it's power from the +AUX and -AUX. It is different to that of the 2250 which uses the 3rd TN. 25 pair cable from console to MDF DB 25 on CIU 26 (w-bl) 14 1 (bl-w) 2 27 (w-or)...
  16. robbot

    CIU power pins

    Hi, I need to add another power TN to my CIU but can't seem to find it documented anywhere. All I can find is one power TN. Surely there is the provision for extra power like the 2250? Any Ideas? Thanks
  17. robbot

    Remote Office Login?

    Hi, Trouble is that I cannot connect to the 9150 using Configuration Mangaler. I cannot establish a serial connection to it and I can't do tftp because I don't lnow the address :( I need to connect manually using procomm and set the IP@. I tried doing the upload command on the 9150 but it...
  18. robbot

    Remote Office Login?

    Hi, I have a remote office 9150 that i need to configure. I know the normal login and password (guest), but that doesn't work. I think I need the low level password. The prompt I have is BO: When I try to set the ip@ I get: BO:setip You must log in before setting up factory information. I...
  19. robbot

    FIR103 PEC X and FIR104 PEC X errors

    Hi, i am getting the following errors on my 81c. FIR103 PEC x and FIR104 PEC x y I have 11 fibre remotes and this error occurs on most of them from time to time. I have checked the fibres and they seem to be ok. Any ideas what could be causing this? They are running over multimode and the...
  20. robbot

    More info on BUG6244

    Hmm, wouldn't surprise me... It is an 81c CP4 running 25.15. It has ini'd a few times though. I thought that was an issue I had with the fibre remotes, maybe a software thing :(

Part and Inventory Search

Back
Top