I'm very new to this, but the following has been working for me
time server1:pool.ntp.org
time server disabled:0
time zone name:GB-London
time server1:server 0.uk.pool.ntp.org
time server2:server 1.uk.pool.ntp.org
time server3:server 2.uk.pool.ntp.org
time server disabled:0
time zone...
Yes in OWS
Options
DNA Directory Control Properties
Internal Directory Configuration
Fonts Tab
Be careful to choose 'List Box Font' in drop down under Property Name:
Choose font, style and size separately it doesn't accept them together, may take a couple of tries but it will eventually save...
We have TSE 3.2 SP3. 11 LIM system.
Exact same incidence here during April. Still ongoing, system is very unstable. Manufacturer suggests a re-build. LIM's have corruption in PU's.
TSE 3.2 SP3 11 LIM system
Following investigation into a problem on the IPLU card finding Corruption in the PU's on the LIM this was then resolved by editing the PU (maintenance service provider did this). Other faults appeared on other LIM's rebuild advised by manufacturer. Resulting in...
Can anyone please point me in the right direction to enable CLI on the OWS screen, at the moment they see the TRK number? It was possible I believe in BC12... I'm on Mx-One TSW. SP1. I've had a look through previous posts in the forum for CLI, Presentation, OWS, CLIP, CLINP. I've done the same...
I'm hoping that I'm not the first to experience this change and that there is an easy solution.
Pre MX-One the operator speech path would work in such a way that during the progress of the call should the status change the speech path would change, say on a recall to the operator the speech...
If you only need a couple then I can let you have some. However, I last obtained 200 from a corporate gift printing company, just didn't have anything printed on the side. They only charged £2.00 a piece. Cheers - Paul
I have a couple of Premicells which are connected to a BTU1 route is set to RODNI to the operator 100. Incoming calls to the port are signalling the same as a single working exchange line. I've been looking at the settings in the ROCAP and RODAP.
Route 10 and 18 are connected to the Mobile...
Hi rfpup - what did you try? The volume can be controlled by the +/- keys whilst on a call. The improvement to the volume is barely noticeable though but it may help. The Plantronics Vista Amplifiers or the GN Netcom GN8000 MPA will improve the volume significantly when used with a headset.
I would like to change the SKI functions on the phones, they are currently SKI0... I'd prefer SKI28 they seem more sensible,I've seen it elsewhere. Searched the forum but no one seems to have broached the subject before.
Your help is appreciated.
slash50 - I've checked and I think you will find too that Programming OPI is not necessary, it is a standard feature of all OWS and Symbolic consoles for the operator to be able to carry out diversions using the codes in the ALEX or Lazy Dog.
The possible explanation of the double press TFR scenario is that the delay on the switch after BC10 for the system to actually carry out the transfer is now noticably longer. I am aware on BC12 that the message, in the screen of a DBC 225, "SERVICE REQUESTED" appears more frequently and for...
The code you describe is to enable to seize specific trunk circuits on your MD. Sometimes for routine testing.
*0*TRU#DEST
Where TRU is the Trunk number of the route, and DEST is the access code for the route.
Where you think that nothing is happening is only that you expect to hear dial tone...
In the UK I think BC13 is the next release which will have the new features, check with your Account Manager and I understand it may be a free upgrade.
Hi - Are you asking for Withheld numbers to be displayed? If so I understand that this facility would only be available to the relevant authority, i.e. emergency service operators or the police.
If I withhold my number I don't expect anyone to be able to see it. #-)
Thanks
Paul
The progress of a call is shown on the console. Therefore no ring tone is delivered. Is there a version for sight impaired operators which may give the signals you need?
Hi again - Just as I posted this the SP called back with the reason for the problem.[surprise]
Are you ready for this? :-)
The powers that be (Swedesville maybe) don't think that this should be a feature to allow an analogue extension to be able to hold a call and dial the emergency number. It...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.